2022High Blood Pressure & Cardiovascular PreventionOpen access

Target Blood Pressure Values in Ambulatory Blood Pressure Monitoring

Katarzyna Lewandowska, Stanisław Wasiliew, Agata Kukfisz, Michał Hofman, Patrycja Woźniak, Artur Radziemski, Łukasz Stryczyński, Dawid Lipski, Andrzej Tykarski, Paweł Uruski

Open full text 7 citations

Abstract

INTRODUCTION: 2018 ESC/ESH guidelines have recommended 24-h ambulatory blood pressure monitoring to assess hypotensive therapy in many circumstances. Recommended target blood pressure in office blood pressure measurements is between 120/70 and 130/80 mmHg. Such targets for 24-h ambulatory blood pressure monitoring lacks. AIM: We aimed to define target values of blood pressure in 24-h ambulatory blood pressure monitoring in hypertensive patients. METHODS: Office blood pressure measurements and 24-h ambulatory blood pressure monitoring data were collected from 1313 hypertensive patients and sorted following increasing systolic (SBP)/diastolic (DBP) blood pressure in office blood pressure measurements. The corresponding 24-h ambulatory blood pressure monitoring to office blood pressure measurements values were calculated. RESULTS: Values 130/80 mmHg in office blood pressure measurements correspond in 24-h ambulatory blood pressure monitoring: night-time SBP/DBP mean: 113.74/66.95 mmHg; daytime SBP/DBP mean: 135.02/81.78 mmHg and 24-h SBP/DBP mean: 130.24/78.73 mmHg. Values 120/70 mmHg in office blood pressure measurements correspond in 24-h ambulatory blood pressure monitoring: night-time SBP/DBP mean: 109.50/63.43 mmHg; daytime SBP/DBP mean: 131.01/78.47 mmHg and 24-h SBP/DBP mean: 126.36/75.31 mmHg. CONCLUSIONS: The proposed blood pressure target values in 24-h ambulatory blood pressure monitoring complement the therapeutic target indicated in the ESC/ESH recommendations and improves 24-h ambulatory blood pressure monitoring usefulness in clinical practice.

Open-access reader

About this research paper

What this paper is about

INTRODUCTION: 2018 ESC/ESH guidelines have recommended 24-h ambulatory blood pressure monitoring to assess hypotensive therapy in many circumstances. Recommended target blood pressure in office blood pressure measurements is between 120/70 and 130/80 mmHg. Such targets for 24-h ambulatory blood pressure monitoring lacks. AIM: We aimed to define target values of blood pressure in 24-h ambulatory blood pressure monitoring in hypertensive patients. METHODS: Office blood pressure measurements and 24-h ambulatory blood pressure monitoring data were collected from 1313 hypertensive patients and sorted following increasing systolic (SBP)/diastolic (DBP) blood pressure in office blood pressure measurements. The corresponding 24-h ambulatory blood pressure monitoring to office blood pressure measurements values were calculated. RESULTS: Values 130/80 mmHg in office blood pressure measurements correspond in 24-h ambulatory blood pressure monitoring: night-time SBP/DBP mean: 113.74/66.95 mmHg; daytime SBP/DBP mean: 135.02/81.78 mmHg and 24-h SBP/DBP mean: 130.24/78.73 mmHg. Values 120/70 mmHg in office blood pressure measurements correspond in 24-h ambulatory blood pressure monitoring: night-time SBP/DBP mean: 109.50/63.43 mmHg; daytime SBP/DBP mean: 131.01/78.47 mmHg and 24-h SBP/DBP mean: 126.36/75.31 mmHg. CONCLUSIONS: The proposed blood pressure target values in 24-h ambulatory blood pressure monitoring complement the therapeutic target indicated in the ESC/ESH recommendations and improves 24-h ambulatory blood pressure monitoring usefulness in clinical practice.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

INTRODUCTION: 2018 ESC/ESH guidelines have recommended 24-h ambulatory blood pressure monitoring to assess hypotensive therapy in many circumstances. Recommended target blood pressure in office blood pressure measurements is between 120/70 and 130/80 mmHg. Such targets for 24-h ambulatory blood pressure monitoring lacks. AIM: We aimed to define target values of blood pressure in 24-h ambulatory blood pressure monitoring in hypertensive patients. METHODS: Office blood pressure measurements and 24-h ambulatory blood pressure monitoring data were collected from 1313 hypertensive patients and sorted following increasing systolic (SBP)/diastolic (DBP) blood pressure in office blood pressure measurements. The corresponding 24-h ambulatory blood pressure monitoring to office blood pressure measurements values were calculated. RESULTS: Values 130/80 mmHg in office blood pressure measurements correspond in 24-h ambulatory blood pressure monitoring: night-time SBP/DBP mean: 113.74/66.95 mmHg; daytime SBP/DBP mean: 135.02/81.78 mmHg and 24-h SBP/DBP mean: 130.24/78.73 mmHg. Values 120/70 mmHg in office blood pressure measurements correspond in 24-h ambulatory blood pressure monitoring: night-time SBP/DBP mean: 109.50/63.43 mmHg; daytime SBP/DBP mean: 131.01/78.47 mmHg and 24-h SBP/DBP mean: 126.36/75.31 mmHg. CONCLUSIONS: The proposed blood pressure target values in 24-h ambulatory blood pressure monitoring complement the therapeutic target indicated in the ESC/ESH recommendations and improves 24-h ambulatory blood pressure monitoring usefulness in clinical practice.

Key concepts: Ambulatory blood pressure, Blood pressure, Medicine, Ambulatory, Cardiology, Diastole, Internal medicine, Anesthesia

Related papers

Back to paper searchBrowse research topicsOriginal source
Target Blood Pressure Values in Ambulatory Blood Pressure Monitoring — Research Paper | ScholarLens