Numerical Simulation Study of Progressive Collapse of Reinforced Concrete Frames with Masonry Infill Walls under Blast Loading
Qinghu Xu, Xuezhi Zhen, Yu Zhang, Mengjun Han, Wenkang Zhang
Abstract
Open-access reader
Qinghu Xu, Xuezhi Zhen, Yu Zhang, Mengjun Han, Wenkang Zhang
Abstract
Open-access reader
The influence of masonry infill walls on the progressive collapse performance of reinforced concrete (RC) frame structures was investigated in this paper, using a nonlinear dynamic analysis approach. Based on ANSYS/LS-DYNA finite element software, two finite element models of RC frame structures with and without masonry infilled walls were established. Then, the collapse modes of the two RC frame structure models were analyzed for different scaled distance blast loads, different locations of column damage, and different span numbers. The results show that with the increase of explosive amount, the collapse degree of the structure is more serious in the same time. Under the condition of destroying the outermost central column, the degree of progressive collapse of the RC frame model with infilled walls in the same time is lower than that of the RC frame model without infilled walls. The RC frame model with infilled walls is more resistant to collapse when the outermost side columns are damaged. With the increase of span number, the structure is more likely to be damaged and collapsed.
OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The influence of masonry infill walls on the progressive collapse performance of reinforced concrete (RC) frame structures was investigated in this paper, using a nonlinear dynamic analysis approach. Based on ANSYS/LS-DYNA finite element software, two finite element models of RC frame structures with and without masonry infilled walls were established. Then, the collapse modes of the two RC frame structure models were analyzed for different scaled distance blast loads, different locations of column damage, and different span numbers. The results show that with the increase of explosive amount, the collapse degree of the structure is more serious in the same time. Under the condition of destroying the outermost central column, the degree of progressive collapse of the RC frame model with infilled walls in the same time is lower than that of the RC frame model without infilled walls. The RC frame model with infilled walls is more resistant to collapse when the outermost side columns are damaged. With the increase of span number, the structure is more likely to be damaged and collapsed.
Key concepts: Structural engineering, Infill, Masonry, Progressive collapse, Finite element method, Reinforced concrete, Frame (networking), Span (engineering)