Development of reference intervals for pupillometry in healthy dogs
Erinn P. Mills, Kelli Combs-Ramey, Grace P. S. Kwong, Daniel Pang
Abstract
Open-access reader
Erinn P. Mills, Kelli Combs-Ramey, Grace P. S. Kwong, Daniel Pang
Abstract
Open-access reader
Background: Pupillometry, the measurement of pupil size and reactivity to a stimulus, has various uses in both human and veterinary medicine. These reflect autonomic tone, with the potential to assess nociception and emotion. Infrared pupillometry reduces inaccuracies that may occur when the pupillary light reflex is determined subjectively by the examiner. To our knowledge, there are no published studies outlining normal reference intervals for automated pupillometry in dogs. Objective: automated pupillometry reference intervals from 126 healthy canine eyes. Methods: The pupillary light reflex (PLR) was measured with a handheld pupillometer (NeurOptics™ PLR-200™ Pupillometer). Parameters recorded included maximum pupil diameter (MAX), minimum pupil diameter (MIN), percent constriction (CON), latency (LAT), average constriction velocity (ACV), maximum constriction velocity (MCV), average dilation velocity (ADV) and time to 75% pupil diameter recovery (T75). One measurement was obtained for each eye. Results: The following reference intervals were developed: MAX (6.05-11.30 mm), MIN (3.76-9.44 mm), CON (-37.89 to -9.64 %), LAT (0.11-0.30 s), ACV (-6.39 to -2.63 mm/ s), MCV (-8.45 to -3.75 mm/s), ADV (-0.21-1.77 mm/s), and T75 (0.49-3.20 s). Clinical significance: The reference intervals developed in this study are an essential first step to facilitate future research exploring pupillometry as a pain assessment method in dogs.
OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Background: Pupillometry, the measurement of pupil size and reactivity to a stimulus, has various uses in both human and veterinary medicine. These reflect autonomic tone, with the potential to assess nociception and emotion. Infrared pupillometry reduces inaccuracies that may occur when the pupillary light reflex is determined subjectively by the examiner. To our knowledge, there are no published studies outlining normal reference intervals for automated pupillometry in dogs. Objective: automated pupillometry reference intervals from 126 healthy canine eyes. Methods: The pupillary light reflex (PLR) was measured with a handheld pupillometer (NeurOptics™ PLR-200™ Pupillometer). Parameters recorded included maximum pupil diameter (MAX), minimum pupil diameter (MIN), percent constriction (CON), latency (LAT), average constriction velocity (ACV), maximum constriction velocity (MCV), average dilation velocity (ADV) and time to 75% pupil diameter recovery (T75). One measurement was obtained for each eye. Results: The following reference intervals were developed: MAX (6.05-11.30 mm), MIN (3.76-9.44 mm), CON (-37.89 to -9.64 %), LAT (0.11-0.30 s), ACV (-6.39 to -2.63 mm/ s), MCV (-8.45 to -3.75 mm/s), ADV (-0.21-1.77 mm/s), and T75 (0.49-3.20 s). Clinical significance: The reference intervals developed in this study are an essential first step to facilitate future research exploring pupillometry as a pain assessment method in dogs.
Key concepts: Pupillometry, Medicine, Optometry, Biology, Pupil, Neuroscience