A Highly Accurate Method for Measuring Response Time of MEMS Thermopiles
Zeqing Xiang, Meng Zhu Shi, Na Zhou, Chenchen Zhang, Xuefeng Ding, Yue Ni, Dapeng Chen, Haiyang Mao
Abstract
Open-access reader
Zeqing Xiang, Meng Zhu Shi, Na Zhou, Chenchen Zhang, Xuefeng Ding, Yue Ni, Dapeng Chen, Haiyang Mao
Abstract
Open-access reader
The response time is an important parameter for thermopiles sensors, which reflects the response speed of the device. The accurate measurement of response time is extremely important to evaluate device characteristics for using them in suitable scenarios. In this work, to accurately measure the response time of thermopile sensors, an Al microheater is integrated in a MEMS thermopile as an in situ heat source. Compared with the traditional chopper measurement method for response time, this approach avoids mechanical delay induced by chopper blades. Accordingly, based on this approach, the response time of the device is measured to be 6.9 ms, while that is 12.7 ms when a chopping system is used, demonstrating that an error of at least 5.8 ms is avoided. Such an approach is quite simple to realize and provides a novel route to accurately measure the response time.
OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The response time is an important parameter for thermopiles sensors, which reflects the response speed of the device. The accurate measurement of response time is extremely important to evaluate device characteristics for using them in suitable scenarios. In this work, to accurately measure the response time of thermopile sensors, an Al microheater is integrated in a MEMS thermopile as an in situ heat source. Compared with the traditional chopper measurement method for response time, this approach avoids mechanical delay induced by chopper blades. Accordingly, based on this approach, the response time of the device is measured to be 6.9 ms, while that is 12.7 ms when a chopping system is used, demonstrating that an error of at least 5.8 ms is avoided. Such an approach is quite simple to realize and provides a novel route to accurately measure the response time.
Key concepts: Thermopile, Response time, Microheater, Chopper, Measure (data warehouse), Microelectromechanical systems, Rise time, Electronic engineering