Isoelectric focusing in agarose: classification of genetic variants of alpha 1-antitrypsin.
G J Buffone, B J Stennis, C M Schimbor
Abstract
G J Buffone, B J Stennis, C M Schimbor
Abstract
Abstract Polyacrylamide has been the matrix of choice for isoelectric focusing owing to the virtual absence of electroendosmosis in this medium. Certain inherent limitations associated with polyacrylamide have prompted some investigators to use low-electroendosmosis agarose for isoelectric focusing, but with limited success thus far. We have developed a method for isoelectric focusing in agarose for the classification of alpha 1-antitrypsin variants. Sera are applied directly to agarose gels containing a pH 4-5 ampholyte mixture, focused for less than 1 h, and directly immunofixed. Resolution of major bands is equivalent to polyacrylamide, and Pi M subtypes can be distinguished without the use of a separator. This application demonstrates the high resolution of isoelectric focusing in agarose, a more practical and convenient matrix than polyacrylamide.
OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Abstract Polyacrylamide has been the matrix of choice for isoelectric focusing owing to the virtual absence of electroendosmosis in this medium. Certain inherent limitations associated with polyacrylamide have prompted some investigators to use low-electroendosmosis agarose for isoelectric focusing, but with limited success thus far. We have developed a method for isoelectric focusing in agarose for the classification of alpha 1-antitrypsin variants. Sera are applied directly to agarose gels containing a pH 4-5 ampholyte mixture, focused for less than 1 h, and directly immunofixed. Resolution of major bands is equivalent to polyacrylamide, and Pi M subtypes can be distinguished without the use of a separator. This application demonstrates the high resolution of isoelectric focusing in agarose, a more practical and convenient matrix than polyacrylamide.
Key concepts: Agarose, Isoelectric focusing, Polyacrylamide, Polyacrylamide gel electrophoresis, Chromatography, Resolution (logic), Isoelectric point, Chemistry