1990Archives of DermatologyRequires access

Bacterial Transference During Electrodesiccation and Electrocoagulation

Richard G. Bennett

Open publisher page 14 citations

Abstract

• Electrodesiccation and electrocoagulation are commonly used to control bleeding and destroy tissue. In certain outpatient settings, the clinician routinely uses one of these electrosurgical modalities on successive patients without sterilization or antisepsis of the treatment electrode tip. In controlled laboratory experiments using electrodesiccation and electrocoagulation, we investigated bacterial transference ofStaphylococcus aureusfrom inoculated tissue to sterile electrode tips and from inoculated electrode tips to sterile tissue. With use on inoculated tissue, sterile electrode tips remained sterile after electrocoagulation but not after electrodesiccation. Bacterial transference from inoculated electrode tips to sterile tissue occurred with electrodesiccation but not with electrocoagulation. These results are consistent with bacterial destruction by electric current and suggest that bacterial transference via the treatment electrosurgery electrode from one patient to another is possible but much more probable during electrodesiccation than during electrocoagulation. (Arch Dermatol. 1990;126:751-755)

About this research paper

What this paper is about

• Electrodesiccation and electrocoagulation are commonly used to control bleeding and destroy tissue. In certain outpatient settings, the clinician routinely uses one of these electrosurgical modalities on successive patients without sterilization or antisepsis of the treatment electrode tip. In controlled laboratory experiments using electrodesiccation and electrocoagulation, we investigated bacterial transference ofStaphylococcus aureusfrom inoculated tissue to sterile electrode tips and from inoculated electrode tips to sterile tissue. With use on inoculated tissue, sterile electrode tips remained sterile after electrocoagulation but not after electrodesiccation. Bacterial transference from inoculated electrode tips to sterile tissue occurred with electrodesiccation but not with electrocoagulation. These results are consistent with bacterial destruction by electric current and suggest that bacterial transference via the treatment electrosurgery electrode from one patient to another is possible but much more probable during electrodesiccation than during electrocoagulation. (Arch Dermatol. 1990;126:751-755)

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

• Electrodesiccation and electrocoagulation are commonly used to control bleeding and destroy tissue. In certain outpatient settings, the clinician routinely uses one of these electrosurgical modalities on successive patients without sterilization or antisepsis of the treatment electrode tip. In controlled laboratory experiments using electrodesiccation and electrocoagulation, we investigated bacterial transference ofStaphylococcus aureusfrom inoculated tissue to sterile electrode tips and from inoculated electrode tips to sterile tissue. With use on inoculated tissue, sterile electrode tips remained sterile after electrocoagulation but not after electrodesiccation. Bacterial transference from inoculated electrode tips to sterile tissue occurred with electrodesiccation but not with electrocoagulation. These results are consistent with bacterial destruction by electric current and suggest that bacterial transference via the treatment electrosurgery electrode from one patient to another is possible but much more probable during electrodesiccation than during electrocoagulation. (Arch Dermatol. 1990;126:751-755)

Key concepts: Electrocoagulation, Electrosurgery, Medicine, Diathermy, Surgery, Sterilization (economics), Economics, Foreign exchange

Related papers

Back to paper searchBrowse research topicsOriginal source
Bacterial Transference During Electrodesiccation and Electrocoagulation — Research Paper | ScholarLens