Application of a modified keratometer in the study of corneal topography on Chinese subjects
Andrew Lam
Abstract
Andrew Lam
Abstract
A corneal topography study was carried out on Hong Kong Chinese subjects using a modified keratometer. The Chinese corneal topography measured by this modified keratometer was similar to other studies using the Wesley–Jessen Photo Electronic Keratoscopy (PEK) System 2000. The mean p-values along the horizontal meridian and the vertical meridian were 0.82 and 0.87, respectively. A negative correlation was found between the p-value and the central corneal radius along the horizontal meridian which may indicate that a steeper central cornea will have a greater p-value. However, the correlation coefficient of 0.56 was not too certain for this conclusion to be drawn. A difference of 0.04 was found between the horizontal p-value and the vertical p-value, which may be a result of the tight lid tension along the vertical meridian. This modified keratometer can be considered as an inexpensive instrument for the study of corneal topography.
OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A corneal topography study was carried out on Hong Kong Chinese subjects using a modified keratometer. The Chinese corneal topography measured by this modified keratometer was similar to other studies using the Wesley–Jessen Photo Electronic Keratoscopy (PEK) System 2000. The mean p-values along the horizontal meridian and the vertical meridian were 0.82 and 0.87, respectively. A negative correlation was found between the p-value and the central corneal radius along the horizontal meridian which may indicate that a steeper central cornea will have a greater p-value. However, the correlation coefficient of 0.56 was not too certain for this conclusion to be drawn. A difference of 0.04 was found between the horizontal p-value and the vertical p-value, which may be a result of the tight lid tension along the vertical meridian. This modified keratometer can be considered as an inexpensive instrument for the study of corneal topography.
Key concepts: Meridian (astronomy), Keratometer, Ophthalmology, Cornea, Geodesy, Significant difference, Correlation coefficient, Corneal topography