Evaluation of multi-wavelength derivative spectra for quantitative applications in clinical chemistry.
W E Weiser, H L Pardue
Abstract
W E Weiser, H L Pardue
Abstract
Abstract We have used the quantitation of methemoglobin in the presence of a light-scattering suspension as a model to evaluate and compare the relative merits of zeroth-, first-, and second-derivative spectroscopy for problems in clinical chemistry. Data for second derivatives are most effective in nullifying the effect of the background spectrum; data for first derivatives are less effective; and data for absorbance (zeroth derivative) are least effective. In one set of experiments, variable amounts of the light-scattering component were added to a methemoglobin solution to increase the apparent absorbance up to about 230% of the absorbance of the original solution. Whereas computation with data for absorbance would have yielded errors approaching 100%, concentrations computed with second-derivative spectral data yielded a systematic error (bias) of only 0.5% and a relative standard deviation (CV) of 1.6%.
OpenAlex reports 18 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Abstract We have used the quantitation of methemoglobin in the presence of a light-scattering suspension as a model to evaluate and compare the relative merits of zeroth-, first-, and second-derivative spectroscopy for problems in clinical chemistry. Data for second derivatives are most effective in nullifying the effect of the background spectrum; data for first derivatives are less effective; and data for absorbance (zeroth derivative) are least effective. In one set of experiments, variable amounts of the light-scattering component were added to a methemoglobin solution to increase the apparent absorbance up to about 230% of the absorbance of the original solution. Whereas computation with data for absorbance would have yielded errors approaching 100%, concentrations computed with second-derivative spectral data yielded a systematic error (bias) of only 0.5% and a relative standard deviation (CV) of 1.6%.
Key concepts: Absorbance, Methemoglobin, Second derivative, Chemistry, Derivative (finance), Analytical Chemistry (journal), Wavelength, Spectroscopy