1983Clinical ChemistryRequires access

Evaluation of multi-wavelength derivative spectra for quantitative applications in clinical chemistry.

W E Weiser, H L Pardue

Open publisher page 18 citations

Abstract

Abstract We have used the quantitation of methemoglobin in the presence of a light-scattering suspension as a model to evaluate and compare the relative merits of zeroth-, first-, and second-derivative spectroscopy for problems in clinical chemistry. Data for second derivatives are most effective in nullifying the effect of the background spectrum; data for first derivatives are less effective; and data for absorbance (zeroth derivative) are least effective. In one set of experiments, variable amounts of the light-scattering component were added to a methemoglobin solution to increase the apparent absorbance up to about 230% of the absorbance of the original solution. Whereas computation with data for absorbance would have yielded errors approaching 100%, concentrations computed with second-derivative spectral data yielded a systematic error (bias) of only 0.5% and a relative standard deviation (CV) of 1.6%.

About this research paper

What this paper is about

Abstract We have used the quantitation of methemoglobin in the presence of a light-scattering suspension as a model to evaluate and compare the relative merits of zeroth-, first-, and second-derivative spectroscopy for problems in clinical chemistry. Data for second derivatives are most effective in nullifying the effect of the background spectrum; data for first derivatives are less effective; and data for absorbance (zeroth derivative) are least effective. In one set of experiments, variable amounts of the light-scattering component were added to a methemoglobin solution to increase the apparent absorbance up to about 230% of the absorbance of the original solution. Whereas computation with data for absorbance would have yielded errors approaching 100%, concentrations computed with second-derivative spectral data yielded a systematic error (bias) of only 0.5% and a relative standard deviation (CV) of 1.6%.

Why it matters

OpenAlex reports 18 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract We have used the quantitation of methemoglobin in the presence of a light-scattering suspension as a model to evaluate and compare the relative merits of zeroth-, first-, and second-derivative spectroscopy for problems in clinical chemistry. Data for second derivatives are most effective in nullifying the effect of the background spectrum; data for first derivatives are less effective; and data for absorbance (zeroth derivative) are least effective. In one set of experiments, variable amounts of the light-scattering component were added to a methemoglobin solution to increase the apparent absorbance up to about 230% of the absorbance of the original solution. Whereas computation with data for absorbance would have yielded errors approaching 100%, concentrations computed with second-derivative spectral data yielded a systematic error (bias) of only 0.5% and a relative standard deviation (CV) of 1.6%.

Key concepts: Absorbance, Methemoglobin, Second derivative, Chemistry, Derivative (finance), Analytical Chemistry (journal), Wavelength, Spectroscopy

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of multi-wavelength derivative spectra for quantitative applications in clinical chemistry. — Research Paper | ScholarLens