1998•PEDIATRICSRequires access

Test for the Concentration of Electrolytes in Cystic Fibrosis of the Pancreas Utilizing Pilocarpine by Iontophoresis, by Lewis E. Gibson and Robert E. Cooke,Pediatrics; 1959;24:545–549

Victor Chernick

Open publisher page 2 citations

Abstract

Aim. To develop a method for stimulating sweating that is rapid, painless, and avoids the risk of heat stress. Background. Since the discovery that there is a high concentration of sodium and chloride in the sweat of patients with cystic fibrosis of the pancreas in 1953, the sweat test has been performed by placing the patient's body in a plastic bag with or without hot water bottles to stimulate sweating. This method is unsatisfactory because of complications such as hyperpyrexia and heat stroke. Direct injection of a cholinergic agent intradermally is painful and therefore not practical. Methods. A rheostat with a milliampere meter was constructed at a cost of ∼$7 that allowed the iontophoresis of pilocarpine into the skin using negative and positive (2-cm diameter) electrocardiography electrodes. The positive electrode was placed on the flexor surface of the arm over a filter paper soaked in 0.2 mL of 0.2% pilocarpine nitrate. Current (0.2 mA) was applied for 5 minutes and then sweat was collected onto a preweighed filter paper for 30 minutes. Sweat chloride was determined by a polarographic method. Sweat tests were performed on 25 patients with cystic fibrosis (CF), 17 asymptomatic relatives and 27 control patients. Patients with CF had sweat chloride concentration >80 mEq/L; relatives, 32.5 mEq/L (highest 57 mEq/L); and control subjects, 21.1 mEq/L (highest 60 mEq/L). Conclusions. The iontophoresis of pilocarpine into the skin is a rapid, painless, safe, and reliable method for stimulating sweating and facilitating the determination of sweat chloride concentration.

About this research paper

What this paper is about

Aim. To develop a method for stimulating sweating that is rapid, painless, and avoids the risk of heat stress. Background. Since the discovery that there is a high concentration of sodium and chloride in the sweat of patients with cystic fibrosis of the pancreas in 1953, the sweat test has been performed by placing the patient's body in a plastic bag with or without hot water bottles to stimulate sweating. This method is unsatisfactory because of complications such as hyperpyrexia and heat stroke. Direct injection of a cholinergic agent intradermally is painful and therefore not practical. Methods. A rheostat with a milliampere meter was constructed at a cost of ∼$7 that allowed the iontophoresis of pilocarpine into the skin using negative and positive (2-cm diameter) electrocardiography electrodes. The positive electrode was placed on the flexor surface of the arm over a filter paper soaked in 0.2 mL of 0.2% pilocarpine nitrate. Current (0.2 mA) was applied for 5 minutes and then sweat was collected onto a preweighed filter paper for 30 minutes. Sweat chloride was determined by a polarographic method. Sweat tests were performed on 25 patients with cystic fibrosis (CF), 17 asymptomatic relatives and 27 control patients. Patients with CF had sweat chloride concentration >80 mEq/L; relatives, 32.5 mEq/L (highest 57 mEq/L); and control subjects, 21.1 mEq/L (highest 60 mEq/L). Conclusions. The iontophoresis of pilocarpine into the skin is a rapid, painless, safe, and reliable method for stimulating sweating and facilitating the determination of sweat chloride concentration.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Aim. To develop a method for stimulating sweating that is rapid, painless, and avoids the risk of heat stress. Background. Since the discovery that there is a high concentration of sodium and chloride in the sweat of patients with cystic fibrosis of the pancreas in 1953, the sweat test has been performed by placing the patient's body in a plastic bag with or without hot water bottles to stimulate sweating. This method is unsatisfactory because of complications such as hyperpyrexia and heat stroke. Direct injection of a cholinergic agent intradermally is painful and therefore not practical. Methods. A rheostat with a milliampere meter was constructed at a cost of ∼$7 that allowed the iontophoresis of pilocarpine into the skin using negative and positive (2-cm diameter) electrocardiography electrodes. The positive electrode was placed on the flexor surface of the arm over a filter paper soaked in 0.2 mL of 0.2% pilocarpine nitrate. Current (0.2 mA) was applied for 5 minutes and then sweat was collected onto a preweighed filter paper for 30 minutes. Sweat chloride was determined by a polarographic method. Sweat tests were performed on 25 patients with cystic fibrosis (CF), 17 asymptomatic relatives and 27 control patients. Patients with CF had sweat chloride concentration >80 mEq/L; relatives, 32.5 mEq/L (highest 57 mEq/L); and control subjects, 21.1 mEq/L (highest 60 mEq/L). Conclusions. The iontophoresis of pilocarpine into the skin is a rapid, painless, safe, and reliable method for stimulating sweating and facilitating the determination of sweat chloride concentration.

Key concepts: SWEAT, Iontophoresis, Medicine, Pilocarpine, Perspiration, Cystic fibrosis, Sweat test, Asymptomatic

Related papers

Back to paper searchBrowse research topicsOriginal source
Test for the Concentration of Electrolytes in Cystic Fibrosis of the Pancreas Utilizing Pilocarpine by Iontophoresis, by Lewis E. Gibson and Robert E. Cooke,Pediatrics; 1959;24:545–549 — Research Paper | ScholarLens