2022PolymersOpen access

Influence of New Sleeve Composite on Fracture Behavior of Anterior Teeth with Flared Root Canals

Shinji Yoshii, Sufyan Garoushi, Chiaki Kitamura, Pekka K. Vallittu, Lippo Lassila

Open full text 0 citations

Abstract

We evaluated the fracture strength and failure mode of non-ferrule teeth with flared root canals that were restored using new experimental sleeve composites. Fifty endodontically treated anterior teeth with flared root canals were restored with direct restorations utilizing different techniques. Group A had teeth (non-ferrule) restored using commercialized MI glass fiber post + Gradia Core as core build-up. Group B had teeth (non-ferrule) restored with commercialized i-TFC glass fiber post + sleeve system. In Group C, the teeth (non-ferrule) were restored with an experimental sleeve composite with commercialized MI glass fiber post and Gradia Core. Group D, teeth (non-ferrule), were restored using custom-made tapered E-glass filling post and Gradia Core. Group E, teeth (with ferrule), were restored with commercialized MI glass fiber post + Gradia Core. After core construction, all specimens underwent direct composite crown restoration and were loaded until fracture using a universal testing machine. Average fracture loads were compared, and the failure modes were observed. Group C exhibited significantly greater fracture strength than other groups (p < 0.05). Favorable fracture teeth ratio of group C was more than that of the other groups. Thus, the new experimental sleeve composite could be clinically useful for core construction of non-ferrule teeth.

About this research paper

What this paper is about

We evaluated the fracture strength and failure mode of non-ferrule teeth with flared root canals that were restored using new experimental sleeve composites. Fifty endodontically treated anterior teeth with flared root canals were restored with direct restorations utilizing different techniques. Group A had teeth (non-ferrule) restored using commercialized MI glass fiber post + Gradia Core as core build-up. Group B had teeth (non-ferrule) restored with commercialized i-TFC glass fiber post + sleeve system. In Group C, the teeth (non-ferrule) were restored with an experimental sleeve composite with commercialized MI glass fiber post and Gradia Core. Group D, teeth (non-ferrule), were restored using custom-made tapered E-glass filling post and Gradia Core. Group E, teeth (with ferrule), were restored with commercialized MI glass fiber post + Gradia Core. After core construction, all specimens underwent direct composite crown restoration and were loaded until fracture using a universal testing machine. Average fracture loads were compared, and the failure modes were observed. Group C exhibited significantly greater fracture strength than other groups (p < 0.05). Favorable fracture teeth ratio of group C was more than that of the other groups. Thus, the new experimental sleeve composite could be clinically useful for core construction of non-ferrule teeth.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We evaluated the fracture strength and failure mode of non-ferrule teeth with flared root canals that were restored using new experimental sleeve composites. Fifty endodontically treated anterior teeth with flared root canals were restored with direct restorations utilizing different techniques. Group A had teeth (non-ferrule) restored using commercialized MI glass fiber post + Gradia Core as core build-up. Group B had teeth (non-ferrule) restored with commercialized i-TFC glass fiber post + sleeve system. In Group C, the teeth (non-ferrule) were restored with an experimental sleeve composite with commercialized MI glass fiber post and Gradia Core. Group D, teeth (non-ferrule), were restored using custom-made tapered E-glass filling post and Gradia Core. Group E, teeth (with ferrule), were restored with commercialized MI glass fiber post + Gradia Core. After core construction, all specimens underwent direct composite crown restoration and were loaded until fracture using a universal testing machine. Average fracture loads were compared, and the failure modes were observed. Group C exhibited significantly greater fracture strength than other groups (p < 0.05). Favorable fracture teeth ratio of group C was more than that of the other groups. Thus, the new experimental sleeve composite could be clinically useful for core construction of non-ferrule teeth.

Key concepts: Root (linguistics), Fracture (geology), Materials science, Composite number, Orthodontics, Dentistry, Composite material, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Influence of New Sleeve Composite on Fracture Behavior of Anterior Teeth with Flared Root Canals — Research Paper | ScholarLens