2022SensorsOpen access

Investigation of Indoor Air Quality in Residential Buildings by Measuring CO2 Concentration and a Questionnaire Survey

Shunichi Hattori, Toshiya Iwamatsu, Teruhisa Miura, Fujio Tsutsumi, Nobuyuki Tanaka

Open full text 30 citations

Abstract

Indoor air quality (IAQ) in houses is often deteriorated by chemical substances emitted from heating, building materials, or other household goods. Since it is difficult for occupants to recognize air pollution, they rarely understand the actual conditions of the IAQ. An investigation into the actual condition of IAQ in houses was therefore conducted in this study. Carbon dioxide (CO2) concentrations in 24 occupied houses was measured, and the results from our analysis showed that the use of combustion heaters increased the concentration of CO2 and led to indoor air pollution. Results indicate that as outdoor temperature decreased, the frequency of ventilation decreased simultaneously, and CO2 concentration increased. Results of the questionnaire survey revealed that the actual IAQ in each house did not match the level of awareness its occupants had regarding ventilation. Along with this difficulty in perceiving air pollution, the lack of knowledge about ventilation systems and the effects of combustion heating may be additional barriers to IAQ awareness.

Open-access reader

About this research paper

What this paper is about

Indoor air quality (IAQ) in houses is often deteriorated by chemical substances emitted from heating, building materials, or other household goods. Since it is difficult for occupants to recognize air pollution, they rarely understand the actual conditions of the IAQ. An investigation into the actual condition of IAQ in houses was therefore conducted in this study. Carbon dioxide (CO2) concentrations in 24 occupied houses was measured, and the results from our analysis showed that the use of combustion heaters increased the concentration of CO2 and led to indoor air pollution. Results indicate that as outdoor temperature decreased, the frequency of ventilation decreased simultaneously, and CO2 concentration increased. Results of the questionnaire survey revealed that the actual IAQ in each house did not match the level of awareness its occupants had regarding ventilation. Along with this difficulty in perceiving air pollution, the lack of knowledge about ventilation systems and the effects of combustion heating may be additional barriers to IAQ awareness.

Why it matters

OpenAlex reports 30 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Indoor air quality (IAQ) in houses is often deteriorated by chemical substances emitted from heating, building materials, or other household goods. Since it is difficult for occupants to recognize air pollution, they rarely understand the actual conditions of the IAQ. An investigation into the actual condition of IAQ in houses was therefore conducted in this study. Carbon dioxide (CO2) concentrations in 24 occupied houses was measured, and the results from our analysis showed that the use of combustion heaters increased the concentration of CO2 and led to indoor air pollution. Results indicate that as outdoor temperature decreased, the frequency of ventilation decreased simultaneously, and CO2 concentration increased. Results of the questionnaire survey revealed that the actual IAQ in each house did not match the level of awareness its occupants had regarding ventilation. Along with this difficulty in perceiving air pollution, the lack of knowledge about ventilation systems and the effects of combustion heating may be additional barriers to IAQ awareness.

Key concepts: Indoor air quality, Ventilation (architecture), Environmental science, Combustion, Air pollution, Environmental engineering, Architectural engineering, Indoor air

Related papers

Back to paper searchBrowse research topicsOriginal source
Investigation of Indoor Air Quality in Residential Buildings by Measuring CO2 Concentration and a Questionnaire Survey — Research Paper | ScholarLens