2022Journal of International Medical ResearchOpen access

Prevention of Blood Donation-related Vasovagal Response by Applied Muscle Tension: a Meta-analysis

Cong Wang, Li Chen, Chenyu Sun, Yan Zhang, Can Cao, Yuanyuan Ma, Wenwen Shi

Open full text 11 citations

Abstract

OBJECTIVE: Vasovagal reaction (VVR) is an adverse reaction to blood donation. Applied muscle tension (AMT) has been reported to reduce the probability of VVR during blood donation; however, the results have been controversial. We therefore conducted a meta-analysis to systematically evaluate the effect of AMT in reducing VVR. METHODS: We searched six major databases using "applied muscle tension" and "blood donation-related vasovagal response" as keywords. Relevant articles published in English or Chinese between 1 January 2000 and 30 June 2021 were included in the analysis. The quality of the included articles was evaluated and publication bias was assessed by forest and funnel plots and by Egger's test. RESULTS: Fifty-one articles were identified, of which six were included according to the pre-defined inclusion and exclusion criteria. A fixed-effects model was adopted for effect size combination and revealed a relative risk of 0.52 (95% confidence interval 0.40 to 0.67). The AMT group was superior to the control in terms of VVR prevention. A funnel plot and Egger's test suggested that the findings were accurate and reliable with low publication bias. CONCLUSION: AMT could effectively reduce VVR during blood donation. Further multicenter studies with large sample sizes are needed to confirm these results.

About this research paper

What this paper is about

OBJECTIVE: Vasovagal reaction (VVR) is an adverse reaction to blood donation. Applied muscle tension (AMT) has been reported to reduce the probability of VVR during blood donation; however, the results have been controversial. We therefore conducted a meta-analysis to systematically evaluate the effect of AMT in reducing VVR. METHODS: We searched six major databases using "applied muscle tension" and "blood donation-related vasovagal response" as keywords. Relevant articles published in English or Chinese between 1 January 2000 and 30 June 2021 were included in the analysis. The quality of the included articles was evaluated and publication bias was assessed by forest and funnel plots and by Egger's test. RESULTS: Fifty-one articles were identified, of which six were included according to the pre-defined inclusion and exclusion criteria. A fixed-effects model was adopted for effect size combination and revealed a relative risk of 0.52 (95% confidence interval 0.40 to 0.67). The AMT group was superior to the control in terms of VVR prevention. A funnel plot and Egger's test suggested that the findings were accurate and reliable with low publication bias. CONCLUSION: AMT could effectively reduce VVR during blood donation. Further multicenter studies with large sample sizes are needed to confirm these results.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: Vasovagal reaction (VVR) is an adverse reaction to blood donation. Applied muscle tension (AMT) has been reported to reduce the probability of VVR during blood donation; however, the results have been controversial. We therefore conducted a meta-analysis to systematically evaluate the effect of AMT in reducing VVR. METHODS: We searched six major databases using "applied muscle tension" and "blood donation-related vasovagal response" as keywords. Relevant articles published in English or Chinese between 1 January 2000 and 30 June 2021 were included in the analysis. The quality of the included articles was evaluated and publication bias was assessed by forest and funnel plots and by Egger's test. RESULTS: Fifty-one articles were identified, of which six were included according to the pre-defined inclusion and exclusion criteria. A fixed-effects model was adopted for effect size combination and revealed a relative risk of 0.52 (95% confidence interval 0.40 to 0.67). The AMT group was superior to the control in terms of VVR prevention. A funnel plot and Egger's test suggested that the findings were accurate and reliable with low publication bias. CONCLUSION: AMT could effectively reduce VVR during blood donation. Further multicenter studies with large sample sizes are needed to confirm these results.

Key concepts: Funnel plot, Meta-analysis, Publication bias, Medicine, Donation, Confidence interval, Inclusion and exclusion criteria, Forest plot

Related papers

Back to paper searchBrowse research topicsOriginal source
Prevention of Blood Donation-related Vasovagal Response by Applied Muscle Tension: a Meta-analysis — Research Paper | ScholarLens