2022Medical MycologyOpen access

P460 The Aspergillus Lateral Flow Assay for the diagnosis of invasive Aspergillosis

Chonglong Liu, Jie Peng, Yuan Zhang, Ying Wang, He Wang, Yan Su, Zeqi Zhou

Open full text 1 citations

Abstract

Abstract Poster session 3, September 23, 2022, 12:30 PM - 1:30 PM Objectives Invasive Aspergillosis (IA) is a life-threatening opportunistic mycosis that occurs in some people with a compromised immune system. The detection of Aspergillus galactomannan (GM) rapidly gained widespread acceptance as part of the diagnostic workup of a patient suspected of IA. Recently, a Novel QuicGM™ Aspergillus Galactomannan Ag Lateral Flow Assay (LFA) from Dynamiker Biotechnology (Tianjin) Co., Ltd. was released as a screening test of IA. It is a fluorescent immunochromatographic cassette test which using a monoclonal antibody against GM and Europium nanoparticles (Eu NP) (Fig. 1). It is a semi-quantitative test which was easy to operate, rapid with portable detection devices, and can be widely accepted by clinical and primary medical (Fig. 2). We conducted a comparative study between the Dynamiker QuicGMTM Aspergillus Galactomannan Ag (LFA) and the Bio-Rad Platelia™. Methods A total of 66 serum samples and 54 BALF samples were collected, 15 serum samples from the College of American Pathologists (CAP) certificated lab were also included in this study. The samples were tested in parallel using the Bio-Rad Platelia™ Aspergillus Ag (ELISA) and Dynamiker QuicGM™ Aspergillus Galactomannan Ag (LFA). Results The total coincidence rate of the two assays was 98.48% (Kappa value was 0.97 >0.75) and 90.74% (Kappa value was 0.81 >0.75) in 66 serum samples and 54 BALF samples respectively. Conclusions The performance of the Dynamiker QuicGM™Aspergillus Galactomannan Ag (LFA) and Bio-Rad Platelia™ Aspergillus Ag (ELISA) were highly consistent, and the performance of Dynamiker Aspergillus Galactomannan kit were all in line with the statement of the manufacturer. The results are accurate and reliable, and it could be used as an aid for the early rapid screening test of IA.

About this research paper

What this paper is about

Abstract Poster session 3, September 23, 2022, 12:30 PM - 1:30 PM Objectives Invasive Aspergillosis (IA) is a life-threatening opportunistic mycosis that occurs in some people with a compromised immune system. The detection of Aspergillus galactomannan (GM) rapidly gained widespread acceptance as part of the diagnostic workup of a patient suspected of IA. Recently, a Novel QuicGM™ Aspergillus Galactomannan Ag Lateral Flow Assay (LFA) from Dynamiker Biotechnology (Tianjin) Co., Ltd. was released as a screening test of IA. It is a fluorescent immunochromatographic cassette test which using a monoclonal antibody against GM and Europium nanoparticles (Eu NP) (Fig. 1). It is a semi-quantitative test which was easy to operate, rapid with portable detection devices, and can be widely accepted by clinical and primary medical (Fig. 2). We conducted a comparative study between the Dynamiker QuicGMTM Aspergillus Galactomannan Ag (LFA) and the Bio-Rad Platelia™. Methods A total of 66 serum samples and 54 BALF samples were collected, 15 serum samples from the College of American Pathologists (CAP) certificated lab were also included in this study. The samples were tested in parallel using the Bio-Rad Platelia™ Aspergillus Ag (ELISA) and Dynamiker QuicGM™ Aspergillus Galactomannan Ag (LFA). Results The total coincidence rate of the two assays was 98.48% (Kappa value was 0.97 >0.75) and 90.74% (Kappa value was 0.81 >0.75) in 66 serum samples and 54 BALF samples respectively. Conclusions The performance of the Dynamiker QuicGM™Aspergillus Galactomannan Ag (LFA) and Bio-Rad Platelia™ Aspergillus Ag (ELISA) were highly consistent, and the performance of Dynamiker Aspergillus Galactomannan kit were all in line with the statement of the manufacturer. The results are accurate and reliable, and it could be used as an aid for the early rapid screening test of IA.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Poster session 3, September 23, 2022, 12:30 PM - 1:30 PM Objectives Invasive Aspergillosis (IA) is a life-threatening opportunistic mycosis that occurs in some people with a compromised immune system. The detection of Aspergillus galactomannan (GM) rapidly gained widespread acceptance as part of the diagnostic workup of a patient suspected of IA. Recently, a Novel QuicGM™ Aspergillus Galactomannan Ag Lateral Flow Assay (LFA) from Dynamiker Biotechnology (Tianjin) Co., Ltd. was released as a screening test of IA. It is a fluorescent immunochromatographic cassette test which using a monoclonal antibody against GM and Europium nanoparticles (Eu NP) (Fig. 1). It is a semi-quantitative test which was easy to operate, rapid with portable detection devices, and can be widely accepted by clinical and primary medical (Fig. 2). We conducted a comparative study between the Dynamiker QuicGMTM Aspergillus Galactomannan Ag (LFA) and the Bio-Rad Platelia™. Methods A total of 66 serum samples and 54 BALF samples were collected, 15 serum samples from the College of American Pathologists (CAP) certificated lab were also included in this study. The samples were tested in parallel using the Bio-Rad Platelia™ Aspergillus Ag (ELISA) and Dynamiker QuicGM™ Aspergillus Galactomannan Ag (LFA). Results The total coincidence rate of the two assays was 98.48% (Kappa value was 0.97 >0.75) and 90.74% (Kappa value was 0.81 >0.75) in 66 serum samples and 54 BALF samples respectively. Conclusions The performance of the Dynamiker QuicGM™Aspergillus Galactomannan Ag (LFA) and Bio-Rad Platelia™ Aspergillus Ag (ELISA) were highly consistent, and the performance of Dynamiker Aspergillus Galactomannan kit were all in line with the statement of the manufacturer. The results are accurate and reliable, and it could be used as an aid for the early rapid screening test of IA.

Key concepts: Galactomannan, Aspergillosis, Aspergillus, Microbiology, Medicine, Immunology, Biology

Related papers

Back to paper searchBrowse research topicsOriginal source
P460 The Aspergillus Lateral Flow Assay for the diagnosis of invasive Aspergillosis — Research Paper | ScholarLens