2022•Journal of Magnetic Resonance OpenOpen access

Double-crossed radiofrequency coil with improved uniformity for rodent MRI at 7 T

O. Marrufo, Fabian Vazquez, R. Martin, Alfredo Odon Rodriguez, Sergio Enrique Solís-Nájera

Open full text 0 citations

Abstract

A transceiver volume coil for High Field Magnetic Resonance Imaging was developed based on Temnikov’s NMR probe coil. The critical advantage of this design is that requires only one trimmer capacitor for both tuning and matching. Electromagnetic simulations of our coil were compared to a four-rung birdcage coil to evaluate their performances. A transceiver coil prototype, called the double-cross coil and a birdcage coil were built to compare and contrast their feasibility. Both coil prototypes were operated in the linear mode. Experimental quality factors were Qu/Ql=101/45 for the double-cross coil and Qu/Ql=105/43 for the birdcage coil. Phantom images were acquired to test the viability of each coil for high field magnetic resonance imaging applications. The signal-to-noise ratios, noise factors and uniformity values were also calculated: 85.26/0.74/44.48 for the double-cross coil and 76.54/1.9/65.65 for the birdcage coil. These volume coils showed similar performance, but the double-cross coil has better uniformity and a slightly lower noise figure than the birdcage coil. A remarkable agreement of experimental and simulated B1 was obtained for the double-cross coil. These experimental and numerical results demonstrate the feasibility of the double-cross volume coil with better uniformity for rodent magnetic resonance imaging at 7 T.

Open-access reader

About this research paper

What this paper is about

A transceiver volume coil for High Field Magnetic Resonance Imaging was developed based on Temnikov’s NMR probe coil. The critical advantage of this design is that requires only one trimmer capacitor for both tuning and matching. Electromagnetic simulations of our coil were compared to a four-rung birdcage coil to evaluate their performances. A transceiver coil prototype, called the double-cross coil and a birdcage coil were built to compare and contrast their feasibility. Both coil prototypes were operated in the linear mode. Experimental quality factors were Qu/Ql=101/45 for the double-cross coil and Qu/Ql=105/43 for the birdcage coil. Phantom images were acquired to test the viability of each coil for high field magnetic resonance imaging applications. The signal-to-noise ratios, noise factors and uniformity values were also calculated: 85.26/0.74/44.48 for the double-cross coil and 76.54/1.9/65.65 for the birdcage coil. These volume coils showed similar performance, but the double-cross coil has better uniformity and a slightly lower noise figure than the birdcage coil. A remarkable agreement of experimental and simulated B1 was obtained for the double-cross coil. These experimental and numerical results demonstrate the feasibility of the double-cross volume coil with better uniformity for rodent magnetic resonance imaging at 7 T.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A transceiver volume coil for High Field Magnetic Resonance Imaging was developed based on Temnikov’s NMR probe coil. The critical advantage of this design is that requires only one trimmer capacitor for both tuning and matching. Electromagnetic simulations of our coil were compared to a four-rung birdcage coil to evaluate their performances. A transceiver coil prototype, called the double-cross coil and a birdcage coil were built to compare and contrast their feasibility. Both coil prototypes were operated in the linear mode. Experimental quality factors were Qu/Ql=101/45 for the double-cross coil and Qu/Ql=105/43 for the birdcage coil. Phantom images were acquired to test the viability of each coil for high field magnetic resonance imaging applications. The signal-to-noise ratios, noise factors and uniformity values were also calculated: 85.26/0.74/44.48 for the double-cross coil and 76.54/1.9/65.65 for the birdcage coil. These volume coils showed similar performance, but the double-cross coil has better uniformity and a slightly lower noise figure than the birdcage coil. A remarkable agreement of experimental and simulated B1 was obtained for the double-cross coil. These experimental and numerical results demonstrate the feasibility of the double-cross volume coil with better uniformity for rodent magnetic resonance imaging at 7 T.

Key concepts: Electromagnetic coil, Coil noise, Radiofrequency coil, Imaging phantom, Search coil, Nuclear magnetic resonance, Coil tap, Materials science

Related papers

Back to paper searchBrowse research topicsOriginal source
Double-crossed radiofrequency coil with improved uniformity for rodent MRI at 7 T — Research Paper | ScholarLens