2022Geriatrics Gerontology and AgingOpen access

Clinimetric properties of a postural assessment software in older people: reliability, standard error of measurement, and minimal detectable change

Juliana Magalhães Machado Barbosa, Thiago Ribeiro Teles Santos, Letícia Aparecida de Oliveira Santos, Thainá Marques Cintra, Rodrigo Beserra Ávila Faccio, Leani Souza Máximo Pereira

Open full text 0 citations

Abstract

Objective: To evaluate intra- and inter-rater reliability, standard error of the measurement (SEM), and minimal detectable change (MDC) of the angles obtained with a Postural Assessment Software (SAPO) in older people. Methods: Postural evaluation of 32 older adults was performed using Postural Assessment Software (SAPO). Two raters performed the procedure independently, and one of the raters repeated the process 7 to 10 days later. Reliability was assessed through the intraclass correlation coefficient (ICC) and paired and independent t-tests. SEM and MDC95 values were calculated, and Bland-Altman plots were generated. Results: The inter-rater analysis showed that the raters were not different in any of the angles. Most angles achieved good to excellent inter-rater reliability (ICC = 0.34 – 0.81) and intrarater reliability (ICC = 0.33 – 0.88) and were not different between days. The SEM was lower than 10º in most angles. The MDC95 ranged from 2.88º to 18.49º. Bland-Altman analysis indicated that most angles were within the limits of agreement. Overall, angles generated in lateral view had better reliability properties. Conclusion: Postural Assessment Software (SAPO) showed angles with distinct reliability properties in older adults. Angles that reached good to excellent intra- and inter-reliability and exhibited lower variability could be considered for assessing postural changes in older adults. MDC95 values could be used as a reference for indicating changes greater than the variability of the measurement.

About this research paper

What this paper is about

Objective: To evaluate intra- and inter-rater reliability, standard error of the measurement (SEM), and minimal detectable change (MDC) of the angles obtained with a Postural Assessment Software (SAPO) in older people. Methods: Postural evaluation of 32 older adults was performed using Postural Assessment Software (SAPO). Two raters performed the procedure independently, and one of the raters repeated the process 7 to 10 days later. Reliability was assessed through the intraclass correlation coefficient (ICC) and paired and independent t-tests. SEM and MDC95 values were calculated, and Bland-Altman plots were generated. Results: The inter-rater analysis showed that the raters were not different in any of the angles. Most angles achieved good to excellent inter-rater reliability (ICC = 0.34 – 0.81) and intrarater reliability (ICC = 0.33 – 0.88) and were not different between days. The SEM was lower than 10º in most angles. The MDC95 ranged from 2.88º to 18.49º. Bland-Altman analysis indicated that most angles were within the limits of agreement. Overall, angles generated in lateral view had better reliability properties. Conclusion: Postural Assessment Software (SAPO) showed angles with distinct reliability properties in older adults. Angles that reached good to excellent intra- and inter-reliability and exhibited lower variability could be considered for assessing postural changes in older adults. MDC95 values could be used as a reference for indicating changes greater than the variability of the measurement.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: To evaluate intra- and inter-rater reliability, standard error of the measurement (SEM), and minimal detectable change (MDC) of the angles obtained with a Postural Assessment Software (SAPO) in older people. Methods: Postural evaluation of 32 older adults was performed using Postural Assessment Software (SAPO). Two raters performed the procedure independently, and one of the raters repeated the process 7 to 10 days later. Reliability was assessed through the intraclass correlation coefficient (ICC) and paired and independent t-tests. SEM and MDC95 values were calculated, and Bland-Altman plots were generated. Results: The inter-rater analysis showed that the raters were not different in any of the angles. Most angles achieved good to excellent inter-rater reliability (ICC = 0.34 – 0.81) and intrarater reliability (ICC = 0.33 – 0.88) and were not different between days. The SEM was lower than 10º in most angles. The MDC95 ranged from 2.88º to 18.49º. Bland-Altman analysis indicated that most angles were within the limits of agreement. Overall, angles generated in lateral view had better reliability properties. Conclusion: Postural Assessment Software (SAPO) showed angles with distinct reliability properties in older adults. Angles that reached good to excellent intra- and inter-reliability and exhibited lower variability could be considered for assessing postural changes in older adults. MDC95 values could be used as a reference for indicating changes greater than the variability of the measurement.

Key concepts: Intraclass correlation, Standard error, Reliability (semiconductor), Limits of agreement, Intra-rater reliability, Statistics, Medicine, Mathematics

Related papers

Back to paper searchBrowse research topicsOriginal source
Clinimetric properties of a postural assessment software in older people: reliability, standard error of measurement, and minimal detectable change — Research Paper | ScholarLens