2022International Journal of Environmental Research and Public HealthOpen access

Respiratory Symptoms and Skin Sick Building Syndrome among Office Workers at University Hospital, Chiang Mai, Thailand: Associations with Indoor Air Quality, AIRMED Project

Vithawat Surawattanasakul, Wachiranun Sirikul, Ratana Sapbamrer, Kampanat Wangsan, Jinjuta Panumasvivat, Pheerasak Assavanopakun, Supang Muangkaew

Open full text 54 citations

Abstract

Sick building syndrome (SBS) is the term used to describe the medical condition in which people in a building suffer from symptoms of illnesses for no apparent reason. SBS was found to be associated with indoor air quality (IAQ) but there are a variety of determinants (buildings, in particular). Identifying and controlling factors related to SBS is crucial for improving worker health and efficiency. A cross-sectional study was conducted to investigate (1) the prevalence of respiratory symptoms and skin SBS and (2) their associations with IAQ among office workers in administrative offices in an academic medical institute. A self-reporting questionnaire assessing the worker’s characteristics, working conditions, and perception of working environments was used. The building assessment was via a walk-through survey and IAQ measurement. Of 290 office workers, 261 (90%) in 25 offices of 11 buildings took part in the survey. The highest prevalence of SBS was nasal symptoms (25.3%). We found that to reduce the risk of SBS, optimal air temperature levels in air-conditioned offices should be lower than 23 °C, with relative humidity between 60% and 70%. Lowering indoor CO2 levels below 700 ppm may be indicative of adequate ventilation to prevent SBS by reducing worker discomfort and indoor contaminants (e.g., formaldehyde).

Open-access reader

About this research paper

What this paper is about

Sick building syndrome (SBS) is the term used to describe the medical condition in which people in a building suffer from symptoms of illnesses for no apparent reason. SBS was found to be associated with indoor air quality (IAQ) but there are a variety of determinants (buildings, in particular). Identifying and controlling factors related to SBS is crucial for improving worker health and efficiency. A cross-sectional study was conducted to investigate (1) the prevalence of respiratory symptoms and skin SBS and (2) their associations with IAQ among office workers in administrative offices in an academic medical institute. A self-reporting questionnaire assessing the worker’s characteristics, working conditions, and perception of working environments was used. The building assessment was via a walk-through survey and IAQ measurement. Of 290 office workers, 261 (90%) in 25 offices of 11 buildings took part in the survey. The highest prevalence of SBS was nasal symptoms (25.3%). We found that to reduce the risk of SBS, optimal air temperature levels in air-conditioned offices should be lower than 23 °C, with relative humidity between 60% and 70%. Lowering indoor CO2 levels below 700 ppm may be indicative of adequate ventilation to prevent SBS by reducing worker discomfort and indoor contaminants (e.g., formaldehyde).

Why it matters

OpenAlex reports 54 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Sick building syndrome (SBS) is the term used to describe the medical condition in which people in a building suffer from symptoms of illnesses for no apparent reason. SBS was found to be associated with indoor air quality (IAQ) but there are a variety of determinants (buildings, in particular). Identifying and controlling factors related to SBS is crucial for improving worker health and efficiency. A cross-sectional study was conducted to investigate (1) the prevalence of respiratory symptoms and skin SBS and (2) their associations with IAQ among office workers in administrative offices in an academic medical institute. A self-reporting questionnaire assessing the worker’s characteristics, working conditions, and perception of working environments was used. The building assessment was via a walk-through survey and IAQ measurement. Of 290 office workers, 261 (90%) in 25 offices of 11 buildings took part in the survey. The highest prevalence of SBS was nasal symptoms (25.3%). We found that to reduce the risk of SBS, optimal air temperature levels in air-conditioned offices should be lower than 23 °C, with relative humidity between 60% and 70%. Lowering indoor CO2 levels below 700 ppm may be indicative of adequate ventilation to prevent SBS by reducing worker discomfort and indoor contaminants (e.g., formaldehyde).

Key concepts: Sick building syndrome, Indoor air quality, Environmental health, Office workers, Medicine, Questionnaire, Indoor air, Ventilation (architecture)

Related papers

Back to paper searchBrowse research topicsOriginal source
Respiratory Symptoms and Skin Sick Building Syndrome among Office Workers at University Hospital, Chiang Mai, Thailand: Associations with Indoor Air Quality, AIRMED Project — Research Paper | ScholarLens