When the measurement information is missing, the Kirchhoff synthetic current method is usually used to replace the current information at the missing measuring point. However, in some specific cases, the inrush current of the transformer and the saturation of the bus CT will occur, which affects the accuracy of the synthetic current, and then leads to the misjudgement of the differential protection using the equivalent current, which endangers the safety and stability of the smart substation and the power system. In this paper, an information loss protection is proposed to eliminate the influence of inrush current and CT saturation, and PSCAD / EMTDC simulation is carried out. The results show that the reliability of power system is effectively improved when the measurement information of transformer and bus connection line is missing.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
When the measurement information is missing, the Kirchhoff synthetic current method is usually used to replace the current information at the missing measuring point. However, in some specific cases, the inrush current of the transformer and the saturation of the bus CT will occur, which affects the accuracy of the synthetic current, and then leads to the misjudgement of the differential protection using the equivalent current, which endangers the safety and stability of the smart substation and the power system. In this paper, an information loss protection is proposed to eliminate the influence of inrush current and CT saturation, and PSCAD / EMTDC simulation is carried out. The results show that the reliability of power system is effectively improved when the measurement information of transformer and bus connection line is missing.
Key concepts: Inrush current, Differential protection, Current transformer, Transformer, Computer science, Electronic engineering, Electric power system, Engineering