2022Journal of Personalized MedicineOpen access

Prospective Evaluation of Two Wall Orbital Fractures Involving the Medial Orbital Wall: PSI Reconstruction versus PDS Repair—Worth the Effort?

Max Wilkat, Karsten Hufendiek, Merve Karahisarlioglu, Maria Borrelli, Christoph Sproll, Majeed Rana

Open full text 11 citations

Abstract

Proper treatment of the two-wall fractured orbit is still controversial. Specifically, there is no consensus on the issue of the necessity of medial orbital wall repair. With anatomically critical structures at risk during the surgical approach, surgeons' view on the necessity of medial orbital wall repair often is restricted and an aesthetically disturbing enophthalmos is more likely to be accepted. Therefore, treatment options range from leaving the medial wall without repair to reconstruction with autogenous tissue or alloplastic materials, which can lead to moderate to severe side effects. However, emerging technologies such as patient-specific implants (PSI) offer a reliable and anatomically correct reconstruction of the bony orbit. This study aimed to evaluate the outcome of full orbital reconstruction using PSIs compared to only orbital floor repair using PDS (bioresorbable polydioxanone) foils leaving the medial orbital wall untouched in traumatic two-wall orbital fractures. Of all patients treated at the University Hospital of Düsseldorf between 2017 and 2019 who suffered from traumatic orbital fracture, only patients with a two-wall orbital fracture involving both the orbital floor and the medial wall (n = 68) were included. Patients were treated either with a PSI (n = 35) or a PDS foil (n = 33). Primary outcome parameters were ophthalmological disturbances analyzed via clinical investigation and intra-orbital angles, volumes and implant position analyzed with radiological 3D-datasets. While a two-wall reconstruction using PSIs led to a significant improvement of the enophthalmos, the rate of postoperative enophthalmos was significantly increased in cases of only orbital floor repair with PDS foils. Radiologically, a significant reconstruction of the three-dimensional bony orbit succeeded with the simple use of PSIs leading to a significant reduction in the traumatically enlarged orbital volume. PSI also led to a significant reduction in the traumatically enlarged medial angle of the orbit. This was not the case for single-floor repair with PDS foil. The results of this study suggest that complex orbital fractures can be reconstructed at an even higher degree of accuracy with selective laser-melted PSIs than PDS foils. In order to achieve a true to original reconstruction of the bony orbit, surgical treatment of the medial orbital wall can be advocated for in the long term depending on the indication.

Open-access reader

About this research paper

What this paper is about

Proper treatment of the two-wall fractured orbit is still controversial. Specifically, there is no consensus on the issue of the necessity of medial orbital wall repair. With anatomically critical structures at risk during the surgical approach, surgeons' view on the necessity of medial orbital wall repair often is restricted and an aesthetically disturbing enophthalmos is more likely to be accepted. Therefore, treatment options range from leaving the medial wall without repair to reconstruction with autogenous tissue or alloplastic materials, which can lead to moderate to severe side effects. However, emerging technologies such as patient-specific implants (PSI) offer a reliable and anatomically correct reconstruction of the bony orbit. This study aimed to evaluate the outcome of full orbital reconstruction using PSIs compared to only orbital floor repair using PDS (bioresorbable polydioxanone) foils leaving the medial orbital wall untouched in traumatic two-wall orbital fractures. Of all patients treated at the University Hospital of Düsseldorf between 2017 and 2019 who suffered from traumatic orbital fracture, only patients with a two-wall orbital fracture involving both the orbital floor and the medial wall (n = 68) were included. Patients were treated either with a PSI (n = 35) or a PDS foil (n = 33). Primary outcome parameters were ophthalmological disturbances analyzed via clinical investigation and intra-orbital angles, volumes and implant position analyzed with radiological 3D-datasets. While a two-wall reconstruction using PSIs led to a significant improvement of the enophthalmos, the rate of postoperative enophthalmos was significantly increased in cases of only orbital floor repair with PDS foils. Radiologically, a significant reconstruction of the three-dimensional bony orbit succeeded with the simple use of PSIs leading to a significant reduction in the traumatically enlarged orbital volume. PSI also led to a significant reduction in the traumatically enlarged medial angle of the orbit. This was not the case for single-floor repair with PDS foil. The results of this study suggest that complex orbital fractures can be reconstructed at an even higher degree of accuracy with selective laser-melted PSIs than PDS foils. In order to achieve a true to original reconstruction of the bony orbit, surgical treatment of the medial orbital wall can be advocated for in the long term depending on the indication.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Proper treatment of the two-wall fractured orbit is still controversial. Specifically, there is no consensus on the issue of the necessity of medial orbital wall repair. With anatomically critical structures at risk during the surgical approach, surgeons' view on the necessity of medial orbital wall repair often is restricted and an aesthetically disturbing enophthalmos is more likely to be accepted. Therefore, treatment options range from leaving the medial wall without repair to reconstruction with autogenous tissue or alloplastic materials, which can lead to moderate to severe side effects. However, emerging technologies such as patient-specific implants (PSI) offer a reliable and anatomically correct reconstruction of the bony orbit. This study aimed to evaluate the outcome of full orbital reconstruction using PSIs compared to only orbital floor repair using PDS (bioresorbable polydioxanone) foils leaving the medial orbital wall untouched in traumatic two-wall orbital fractures. Of all patients treated at the University Hospital of Düsseldorf between 2017 and 2019 who suffered from traumatic orbital fracture, only patients with a two-wall orbital fracture involving both the orbital floor and the medial wall (n = 68) were included. Patients were treated either with a PSI (n = 35) or a PDS foil (n = 33). Primary outcome parameters were ophthalmological disturbances analyzed via clinical investigation and intra-orbital angles, volumes and implant position analyzed with radiological 3D-datasets. While a two-wall reconstruction using PSIs led to a significant improvement of the enophthalmos, the rate of postoperative enophthalmos was significantly increased in cases of only orbital floor repair with PDS foils. Radiologically, a significant reconstruction of the three-dimensional bony orbit succeeded with the simple use of PSIs leading to a significant reduction in the traumatically enlarged orbital volume. PSI also led to a significant reduction in the traumatically enlarged medial angle of the orbit. This was not the case for single-floor repair with PDS foil. The results of this study suggest that complex orbital fractures can be reconstructed at an even higher degree of accuracy with selective laser-melted PSIs than PDS foils. In order to achieve a true to original reconstruction of the bony orbit, surgical treatment of the medial orbital wall can be advocated for in the long term depending on the indication.

Key concepts: Enophthalmos, Medial wall, Medicine, Orbital Fracture, Orbit (dynamics), Surgery, Implant, Lateral wall

Related papers

Back to paper searchBrowse research topicsOriginal source
Prospective Evaluation of Two Wall Orbital Fractures Involving the Medial Orbital Wall: PSI Reconstruction versus PDS Repair—Worth the Effort? — Research Paper | ScholarLens