Application of solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) and comparison of both detection techniques (DAD and FLD) to analyse nesfatin-1 in fetal bovine serum samples
Tomasz Tuzimski, Michał Szubartowski
Abstract
Tomasz Tuzimski, Michał Szubartowski
Abstract
Abstract In this study, we propose a simple, cost-effective, and sensitive high-performance liquid chromatography with both detection techniques such as diode-array detection and fluorescence detection (HPLC-DAD-FLD) for the determination of nesfatin-1 in fetal bovine serum samples. The limit of detection (LOD) and limit of quantification (LOQ) for nesfatin-1 were set at satisfactory values in the range 0.22–0.35 mg mL−1 and in the range 0.67–1.05 mg mL−1, respectively (at two different wavelengths (DAD) and at four different wavelengths (FLD)). Analyte concentrations were determined as the average value from fetal bovine serum matrix samples. The preliminary results show that the SPE procedure on Isolute Si-TsOH (SCX-3) could be used for further nesfatin-1 analyses in human serum samples. Both the SPE technique, chromatographic analysis with gradient elution mode and detection technique are fast and convenient.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Abstract In this study, we propose a simple, cost-effective, and sensitive high-performance liquid chromatography with both detection techniques such as diode-array detection and fluorescence detection (HPLC-DAD-FLD) for the determination of nesfatin-1 in fetal bovine serum samples. The limit of detection (LOD) and limit of quantification (LOQ) for nesfatin-1 were set at satisfactory values in the range 0.22–0.35 mg mL−1 and in the range 0.67–1.05 mg mL−1, respectively (at two different wavelengths (DAD) and at four different wavelengths (FLD)). Analyte concentrations were determined as the average value from fetal bovine serum matrix samples. The preliminary results show that the SPE procedure on Isolute Si-TsOH (SCX-3) could be used for further nesfatin-1 analyses in human serum samples. Both the SPE technique, chromatographic analysis with gradient elution mode and detection technique are fast and convenient.
Key concepts: Chromatography, Detection limit, Chemistry, Analyte, High-performance liquid chromatography, Solid phase extraction, Extraction (chemistry), Elution