2022Unpublished venueRequires access

Fractal Time Series Analysis by Using Entropy and Hurst Exponent

Еvgeniya Gospodinova

Open publisher page 12 citations

Abstract

The paper discusses the analysis of simulated and real fractal time series by applying approximate entropy (ApEn) and sample entropy (SampEn) to determine the complexity and predictability of the time series. The simulated fractal time series are based on the Fractal Gaussian Noise with different values of the Hurst exponent and different lengths. To study the accuracy of the simulated time series, the method of detrended fluctuation analysis was applied, which determines the value of the Hurst exponent. The results obtained on the basis of relative standard error (RSE) show that the simulated time series have a high degree of accuracy, as the RSE is less than 2% for all input values of the Hurst exponent. Studies show that ApEn and SampEn are methods that are very sensitive to input parameters: subseries length, tolerance value and data length. Due to the fact that there is no consensus on the choice of values for these parameters, in the article they are studied on simulated fractal time series with lengths of 600-3000 points. The values of ApEn, SampEn and the value of the Hurst exponent were found to be negatively correlated, and the predictability was positively related to the Hurst exponent. Both entropy-based methods and the Hurst exponent were used to study the dynamics of the behavior of real-time series related to heart rate intervals (RR interval series) to extract useful information related to the influence of the age of the subjects. The results show that the values of ApEn and SampEn are higher for young subjects than for adults, therefore the RR time series of young subjects is more complex than the time series of adult subjects. The value of the Hurst exponent of young subjects was found to be lower than that of adult subjects, therefore the time series of adult subjects have a higher degree of self-similarity. The results reported in this study may be useful in analysing cardiac data to extract useful information in clinical decision making.

About this research paper

What this paper is about

The paper discusses the analysis of simulated and real fractal time series by applying approximate entropy (ApEn) and sample entropy (SampEn) to determine the complexity and predictability of the time series. The simulated fractal time series are based on the Fractal Gaussian Noise with different values of the Hurst exponent and different lengths. To study the accuracy of the simulated time series, the method of detrended fluctuation analysis was applied, which determines the value of the Hurst exponent. The results obtained on the basis of relative standard error (RSE) show that the simulated time series have a high degree of accuracy, as the RSE is less than 2% for all input values of the Hurst exponent. Studies show that ApEn and SampEn are methods that are very sensitive to input parameters: subseries length, tolerance value and data length. Due to the fact that there is no consensus on the choice of values for these parameters, in the article they are studied on simulated fractal time series with lengths of 600-3000 points. The values of ApEn, SampEn and the value of the Hurst exponent were found to be negatively correlated, and the predictability was positively related to the Hurst exponent. Both entropy-based methods and the Hurst exponent were used to study the dynamics of the behavior of real-time series related to heart rate intervals (RR interval series) to extract useful information related to the influence of the age of the subjects. The results show that the values of ApEn and SampEn are higher for young subjects than for adults, therefore the RR time series of young subjects is more complex than the time series of adult subjects. The value of the Hurst exponent of young subjects was found to be lower than that of adult subjects, therefore the time series of adult subjects have a higher degree of self-similarity. The results reported in this study may be useful in analysing cardiac data to extract useful information in clinical decision making.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The paper discusses the analysis of simulated and real fractal time series by applying approximate entropy (ApEn) and sample entropy (SampEn) to determine the complexity and predictability of the time series. The simulated fractal time series are based on the Fractal Gaussian Noise with different values of the Hurst exponent and different lengths. To study the accuracy of the simulated time series, the method of detrended fluctuation analysis was applied, which determines the value of the Hurst exponent. The results obtained on the basis of relative standard error (RSE) show that the simulated time series have a high degree of accuracy, as the RSE is less than 2% for all input values of the Hurst exponent. Studies show that ApEn and SampEn are methods that are very sensitive to input parameters: subseries length, tolerance value and data length. Due to the fact that there is no consensus on the choice of values for these parameters, in the article they are studied on simulated fractal time series with lengths of 600-3000 points. The values of ApEn, SampEn and the value of the Hurst exponent were found to be negatively correlated, and the predictability was positively related to the Hurst exponent. Both entropy-based methods and the Hurst exponent were used to study the dynamics of the behavior of real-time series related to heart rate intervals (RR interval series) to extract useful information related to the influence of the age of the subjects. The results show that the values of ApEn and SampEn are higher for young subjects than for adults, therefore the RR time series of young subjects is more complex than the time series of adult subjects. The value of the Hurst exponent of young subjects was found to be lower than that of adult subjects, therefore the time series of adult subjects have a higher degree of self-similarity. The results reported in this study may be useful in analysing cardiac data to extract useful information in clinical decision making.

Key concepts: Hurst exponent, Detrended fluctuation analysis, Approximate entropy, Sample entropy, Predictability, Fractal, Mathematics, Rescaled range

Related papers

Back to paper searchBrowse research topicsOriginal source
Fractal Time Series Analysis by Using Entropy and Hurst Exponent — Research Paper | ScholarLens