2022Applied Water ScienceOpen access

Characterization of basaltic rock aquifer parameters using hydraulic parameters, Theis’s method and aquifer test software in the hard rock area of Buchakewadi watershed Maharashtra, India

Sachin P. Shinde, V. N. Barai, Nadhir Al‐Ansari, B. K. Gavit, S. A. Kadam, A. A. Atre, R. D. Bansod, Ahmed Elbeltagi

Open full text 7 citations

Abstract

Abstract The twelve wells were selected to carry out the various test, duration of pumping (min), maximum draw drown (m), duration of recovery (min), residual drawdown, and aquifer type in the basaltic rock aquifer parameters of Buchakewadi watershed. The source and flow of groundwater are essential concerns in hydrological systems that concern both spatially and temporally components of groundwater discharge and water supply problems. The content and temperature of groundwater flowing through an aquifer might change depending on the aquifer environment. As a result, hydrodynamic analyses can provide valuable information about a region's subsurface geology. The present research attempts of aquifer variables such as transmissivity (T) and storativity (S) estimation are significant for groundwater resource development and evaluation. There are numerous approaches for calculating precise aquifer characteristics (i.e., hydrograph analysis, pumping test, etc.). A most frequent in situ analysis is a well-pumping test, which accurately measures the decline and rise of groundwater levels. During an aquifer pumping test, to characterize aquifer properties in an undiscovered location to forecast the rate of depletion of the groundwater table/potentiometric surface. The shallow, weathering subsurface water accessible above the Deccan traps in an unconfined state is insufficient to satisfy the ever-increasing pressure on water supplies. Maharashtra is similarly dominated by hard rocks, whose rainfall susceptibility is limited by weathering and primary porosity, as is their volume to store and convey water. Based on the hydraulic parameters and Theis method, results are optimized. Aquifer mapping and pumping test results can be more important for solving problems such as water scarcity, nonpolluting water, health issues, and source of fresh water on the earth surface. However, the characterization of aquifer parameters should be significant role in the scientific planning and engineering practices.

Open-access reader

About this research paper

What this paper is about

Abstract The twelve wells were selected to carry out the various test, duration of pumping (min), maximum draw drown (m), duration of recovery (min), residual drawdown, and aquifer type in the basaltic rock aquifer parameters of Buchakewadi watershed. The source and flow of groundwater are essential concerns in hydrological systems that concern both spatially and temporally components of groundwater discharge and water supply problems. The content and temperature of groundwater flowing through an aquifer might change depending on the aquifer environment. As a result, hydrodynamic analyses can provide valuable information about a region's subsurface geology. The present research attempts of aquifer variables such as transmissivity (T) and storativity (S) estimation are significant for groundwater resource development and evaluation. There are numerous approaches for calculating precise aquifer characteristics (i.e., hydrograph analysis, pumping test, etc.). A most frequent in situ analysis is a well-pumping test, which accurately measures the decline and rise of groundwater levels. During an aquifer pumping test, to characterize aquifer properties in an undiscovered location to forecast the rate of depletion of the groundwater table/potentiometric surface. The shallow, weathering subsurface water accessible above the Deccan traps in an unconfined state is insufficient to satisfy the ever-increasing pressure on water supplies. Maharashtra is similarly dominated by hard rocks, whose rainfall susceptibility is limited by weathering and primary porosity, as is their volume to store and convey water. Based on the hydraulic parameters and Theis method, results are optimized. Aquifer mapping and pumping test results can be more important for solving problems such as water scarcity, nonpolluting water, health issues, and source of fresh water on the earth surface. However, the characterization of aquifer parameters should be significant role in the scientific planning and engineering practices.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract The twelve wells were selected to carry out the various test, duration of pumping (min), maximum draw drown (m), duration of recovery (min), residual drawdown, and aquifer type in the basaltic rock aquifer parameters of Buchakewadi watershed. The source and flow of groundwater are essential concerns in hydrological systems that concern both spatially and temporally components of groundwater discharge and water supply problems. The content and temperature of groundwater flowing through an aquifer might change depending on the aquifer environment. As a result, hydrodynamic analyses can provide valuable information about a region's subsurface geology. The present research attempts of aquifer variables such as transmissivity (T) and storativity (S) estimation are significant for groundwater resource development and evaluation. There are numerous approaches for calculating precise aquifer characteristics (i.e., hydrograph analysis, pumping test, etc.). A most frequent in situ analysis is a well-pumping test, which accurately measures the decline and rise of groundwater levels. During an aquifer pumping test, to characterize aquifer properties in an undiscovered location to forecast the rate of depletion of the groundwater table/potentiometric surface. The shallow, weathering subsurface water accessible above the Deccan traps in an unconfined state is insufficient to satisfy the ever-increasing pressure on water supplies. Maharashtra is similarly dominated by hard rocks, whose rainfall susceptibility is limited by weathering and primary porosity, as is their volume to store and convey water. Based on the hydraulic parameters and Theis method, results are optimized. Aquifer mapping and pumping test results can be more important for solving problems such as water scarcity, nonpolluting water, health issues, and source of fresh water on the earth surface. However, the characterization of aquifer parameters should be significant role in the scientific planning and engineering practices.

Key concepts: Aquifer, Aquifer test, Groundwater, Geology, Hydrogeology, Cone of depression, Well test (oil and gas), Water table

Related papers

Back to paper searchBrowse research topicsOriginal source
Characterization of basaltic rock aquifer parameters using hydraulic parameters, Theis’s method and aquifer test software in the hard rock area of Buchakewadi watershed Maharashtra, India — Research Paper | ScholarLens