2022Scientific ReportsOpen access

Research on smoke control for an underground mall fire, based on smoke barrier and mechanical smoke exhaust system

Jinzhang Jia, Tian Xiuyuan, Fengxiao Wang

Open full text 11 citations

Abstract

This study examines smoke spread in an underground mall fire under the composite smoke control mode of a smoke barrier and a mechanical smoke exhaust system. The objective is to optimize the selection of smoke containment and exhaust methods in an underground mall in Fuxin City, China. A Fire Dynamics Simulator was used for numerical simulation to investigate the effects of the sagging height and spacing of smoke barriers on smoke containment, as well as the effects of size, number, and arrangement of smoke vents in the mechanical smoke exhaust system on the effectiveness of smoke exhaust. The results indicated that a smoke barrier with a sagging height of 1 m and a spacing of 5 m was effective in preventing the spread of high-temperature smoke. When the sagging height of the smoke barrier increased to 1.2 m, the smoke barrier effect was comparable to that of a 1 m height barrier. Regarding the mechanical smoke exhaust system, the size of the opening area of the smoke vent had no significant effect on the smoke exhaust effect. The best smoke exhaust effect was achieved when the number of smoke vents was 12. Additionally, the double-row setting of smoke vents was more efficient than the single-row setting. Combining a smoke barrier and a mechanical smoke exhaust system can provide a more effective smoke control compared to either system alone. Comprehensively, considering the effectiveness and economy of smoke containment and exhaust, the optimal combination of smoke containment and exhaust was determined to be a smoke barrier with a sagging height of 1 m and spacing of 5 m, and a mechanical smoke exhaust system with 12 smoke vents in a double-row arrangement.

Open-access reader

About this research paper

What this paper is about

This study examines smoke spread in an underground mall fire under the composite smoke control mode of a smoke barrier and a mechanical smoke exhaust system. The objective is to optimize the selection of smoke containment and exhaust methods in an underground mall in Fuxin City, China. A Fire Dynamics Simulator was used for numerical simulation to investigate the effects of the sagging height and spacing of smoke barriers on smoke containment, as well as the effects of size, number, and arrangement of smoke vents in the mechanical smoke exhaust system on the effectiveness of smoke exhaust. The results indicated that a smoke barrier with a sagging height of 1 m and a spacing of 5 m was effective in preventing the spread of high-temperature smoke. When the sagging height of the smoke barrier increased to 1.2 m, the smoke barrier effect was comparable to that of a 1 m height barrier. Regarding the mechanical smoke exhaust system, the size of the opening area of the smoke vent had no significant effect on the smoke exhaust effect. The best smoke exhaust effect was achieved when the number of smoke vents was 12. Additionally, the double-row setting of smoke vents was more efficient than the single-row setting. Combining a smoke barrier and a mechanical smoke exhaust system can provide a more effective smoke control compared to either system alone. Comprehensively, considering the effectiveness and economy of smoke containment and exhaust, the optimal combination of smoke containment and exhaust was determined to be a smoke barrier with a sagging height of 1 m and spacing of 5 m, and a mechanical smoke exhaust system with 12 smoke vents in a double-row arrangement.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study examines smoke spread in an underground mall fire under the composite smoke control mode of a smoke barrier and a mechanical smoke exhaust system. The objective is to optimize the selection of smoke containment and exhaust methods in an underground mall in Fuxin City, China. A Fire Dynamics Simulator was used for numerical simulation to investigate the effects of the sagging height and spacing of smoke barriers on smoke containment, as well as the effects of size, number, and arrangement of smoke vents in the mechanical smoke exhaust system on the effectiveness of smoke exhaust. The results indicated that a smoke barrier with a sagging height of 1 m and a spacing of 5 m was effective in preventing the spread of high-temperature smoke. When the sagging height of the smoke barrier increased to 1.2 m, the smoke barrier effect was comparable to that of a 1 m height barrier. Regarding the mechanical smoke exhaust system, the size of the opening area of the smoke vent had no significant effect on the smoke exhaust effect. The best smoke exhaust effect was achieved when the number of smoke vents was 12. Additionally, the double-row setting of smoke vents was more efficient than the single-row setting. Combining a smoke barrier and a mechanical smoke exhaust system can provide a more effective smoke control compared to either system alone. Comprehensively, considering the effectiveness and economy of smoke containment and exhaust, the optimal combination of smoke containment and exhaust was determined to be a smoke barrier with a sagging height of 1 m and spacing of 5 m, and a mechanical smoke exhaust system with 12 smoke vents in a double-row arrangement.

Key concepts: Smoke, Environmental science, Waste management, Containment (computer programming), Environmental engineering, Engineering, Computer science, Programming language

Related papers

Back to paper searchBrowse research topicsOriginal source
Research on smoke control for an underground mall fire, based on smoke barrier and mechanical smoke exhaust system — Research Paper | ScholarLens