Accuracy of MRI in Diagnosis of Invasive Placenta by Taking Per Operative Findings as Gold Standard
Muhammad Talha, Muhammad Wasim Awan, Mashkoor Ahmad, Mahjabeen Mahmood Kamal, N. Usmani, Hassan Mumtaz
Abstract
Open-access reader
Muhammad Talha, Muhammad Wasim Awan, Mashkoor Ahmad, Mahjabeen Mahmood Kamal, N. Usmani, Hassan Mumtaz
Abstract
Open-access reader
Objective: To assess the diagnostic accuracy of magnetic resonance imaging (MRI) in detecting invasive placentas using per-operative findings as the gold standard.Methodology: A prospective cross-sectional study was conducted in the diagnostic radiology department of KRL General Hospital Islamabad during Oct 2019 to Sep 2021. Sixty prenatal individuals were identified as having a high risk of invasive placenta and underwent MRI (Phillips 1.5 T) to confirm the diagnosis. A trainee radiologist and a consultant radiologist reviewed the images. The MRI's sensitivity, specificity, positive predictive value, negative predictive value, and accuracy was calculated using a 2×2 contingency tables. Results: Ten cases of invasive placenta were detected postoperatively (gold standard). The MRI had a sensitivity of 90%, a specificity of 93%, a positive predictive value of 90%, a negative predictive value of 90%, and an accuracy of 92.3 percent, respectively. Conclusion: The study concluded that magnetic resonance imaging (MRI) offers a good diagnostic accuracy and is a reproducible technology for prenatal identification of invasive placentas.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective: To assess the diagnostic accuracy of magnetic resonance imaging (MRI) in detecting invasive placentas using per-operative findings as the gold standard.Methodology: A prospective cross-sectional study was conducted in the diagnostic radiology department of KRL General Hospital Islamabad during Oct 2019 to Sep 2021. Sixty prenatal individuals were identified as having a high risk of invasive placenta and underwent MRI (Phillips 1.5 T) to confirm the diagnosis. A trainee radiologist and a consultant radiologist reviewed the images. The MRI's sensitivity, specificity, positive predictive value, negative predictive value, and accuracy was calculated using a 2×2 contingency tables. Results: Ten cases of invasive placenta were detected postoperatively (gold standard). The MRI had a sensitivity of 90%, a specificity of 93%, a positive predictive value of 90%, a negative predictive value of 90%, and an accuracy of 92.3 percent, respectively. Conclusion: The study concluded that magnetic resonance imaging (MRI) offers a good diagnostic accuracy and is a reproducible technology for prenatal identification of invasive placentas.
Key concepts: Gold standard (test), Medicine, Magnetic resonance imaging, Predictive value, Diagnostic accuracy, Radiology, Positive predicative value, Predictive value of tests