2022Annals of PIMS-Shaheed Zulfiqar Ali Bhutto Medical UniversityOpen access

Accuracy of MRI in Diagnosis of Invasive Placenta by Taking Per Operative Findings as Gold Standard

Muhammad Talha, Muhammad Wasim Awan, Mashkoor Ahmad, Mahjabeen Mahmood Kamal, N. Usmani, Hassan Mumtaz

Open full text 0 citations

Abstract

Objective: To assess the diagnostic accuracy of magnetic resonance imaging (MRI) in detecting invasive placentas using per-operative findings as the gold standard.Methodology: A prospective cross-sectional study was conducted in the diagnostic radiology department of KRL General Hospital Islamabad during Oct 2019 to Sep 2021. Sixty prenatal individuals were identified as having a high risk of invasive placenta and underwent MRI (Phillips 1.5 T) to confirm the diagnosis. A trainee radiologist and a consultant radiologist reviewed the images. The MRI's sensitivity, specificity, positive predictive value, negative predictive value, and accuracy was calculated using a 2×2 contingency tables. Results: Ten cases of invasive placenta were detected postoperatively (gold standard). The MRI had a sensitivity of 90%, a specificity of 93%, a positive predictive value of 90%, a negative predictive value of 90%, and an accuracy of 92.3 percent, respectively. Conclusion: The study concluded that magnetic resonance imaging (MRI) offers a good diagnostic accuracy and is a reproducible technology for prenatal identification of invasive placentas.

Open-access reader

About this research paper

What this paper is about

Objective: To assess the diagnostic accuracy of magnetic resonance imaging (MRI) in detecting invasive placentas using per-operative findings as the gold standard.Methodology: A prospective cross-sectional study was conducted in the diagnostic radiology department of KRL General Hospital Islamabad during Oct 2019 to Sep 2021. Sixty prenatal individuals were identified as having a high risk of invasive placenta and underwent MRI (Phillips 1.5 T) to confirm the diagnosis. A trainee radiologist and a consultant radiologist reviewed the images. The MRI's sensitivity, specificity, positive predictive value, negative predictive value, and accuracy was calculated using a 2×2 contingency tables. Results: Ten cases of invasive placenta were detected postoperatively (gold standard). The MRI had a sensitivity of 90%, a specificity of 93%, a positive predictive value of 90%, a negative predictive value of 90%, and an accuracy of 92.3 percent, respectively. Conclusion: The study concluded that magnetic resonance imaging (MRI) offers a good diagnostic accuracy and is a reproducible technology for prenatal identification of invasive placentas.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: To assess the diagnostic accuracy of magnetic resonance imaging (MRI) in detecting invasive placentas using per-operative findings as the gold standard.Methodology: A prospective cross-sectional study was conducted in the diagnostic radiology department of KRL General Hospital Islamabad during Oct 2019 to Sep 2021. Sixty prenatal individuals were identified as having a high risk of invasive placenta and underwent MRI (Phillips 1.5 T) to confirm the diagnosis. A trainee radiologist and a consultant radiologist reviewed the images. The MRI's sensitivity, specificity, positive predictive value, negative predictive value, and accuracy was calculated using a 2×2 contingency tables. Results: Ten cases of invasive placenta were detected postoperatively (gold standard). The MRI had a sensitivity of 90%, a specificity of 93%, a positive predictive value of 90%, a negative predictive value of 90%, and an accuracy of 92.3 percent, respectively. Conclusion: The study concluded that magnetic resonance imaging (MRI) offers a good diagnostic accuracy and is a reproducible technology for prenatal identification of invasive placentas.

Key concepts: Gold standard (test), Medicine, Magnetic resonance imaging, Predictive value, Diagnostic accuracy, Radiology, Positive predicative value, Predictive value of tests

Related papers

Back to paper searchBrowse research topicsOriginal source
Accuracy of MRI in Diagnosis of Invasive Placenta by Taking Per Operative Findings as Gold Standard — Research Paper | ScholarLens