2022Surgical EndoscopyOpen access

Flexible endoscopy in the visualization of 3D-printed maxillary sinus and clinical application

Zhengrong Xu, Xin Zhang, Xin Dou, Chuanyao Lin, Handong Wang, Shenghua Song, Chenjie Yu, Xinyan Cui, Xia Gao

Open full text 9 citations

Abstract

BACKGROUND: During postoperative follow-up, the visible range of maxillary sinus (MS) is limited, even combining 0° and 70° rigid endoscopes together. Flexible endoscope has been used in larynx examinations for a long time, but rarely in nasal cavity and sinus. We aimed to evaluate the application values of rigid and flexible endoscopes for visualization of MS. METHODS: We followed up 70 patients with lesions in MS via both rigid and flexible endoscopes. In addition, we used thin-slice CT image of the sinus to create a MS model and divided it into two parts for 3D printing. The inner surface of the 3D-printed sinus was marked with grid papers of the same size (5 mm × 5 mm), then the visual range under rigid endoscopes with different angle and flexible endoscopes was calculated and analyzed. RESULTS: In clinical follow-up, we found that flexible endoscopy can reach where rigid endoscopy cannot, which is more sensitive than medical imaging. Endoscopes showed the largest observation range of the posterolateral wall, more than half of which can be visualized by 0° endoscope. Almost all of the posterolateral wall can be revealed under 45° endoscope, 70° endoscope and flexible endoscope. The visual range of each wall under flexible endoscope is generally greater than that under rigid endoscopes, especially of the anterior wall, medial wall and inferior wall. CONCLUSION: There was obviously overall advantage of using flexible endoscope in postoperative follow-up of MS lesions. Flexible endoscopy can expand the range of observation, and improve the early detection of the recurrent lesion. We recommend flexible endoscope as a routine application.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: During postoperative follow-up, the visible range of maxillary sinus (MS) is limited, even combining 0° and 70° rigid endoscopes together. Flexible endoscope has been used in larynx examinations for a long time, but rarely in nasal cavity and sinus. We aimed to evaluate the application values of rigid and flexible endoscopes for visualization of MS. METHODS: We followed up 70 patients with lesions in MS via both rigid and flexible endoscopes. In addition, we used thin-slice CT image of the sinus to create a MS model and divided it into two parts for 3D printing. The inner surface of the 3D-printed sinus was marked with grid papers of the same size (5 mm × 5 mm), then the visual range under rigid endoscopes with different angle and flexible endoscopes was calculated and analyzed. RESULTS: In clinical follow-up, we found that flexible endoscopy can reach where rigid endoscopy cannot, which is more sensitive than medical imaging. Endoscopes showed the largest observation range of the posterolateral wall, more than half of which can be visualized by 0° endoscope. Almost all of the posterolateral wall can be revealed under 45° endoscope, 70° endoscope and flexible endoscope. The visual range of each wall under flexible endoscope is generally greater than that under rigid endoscopes, especially of the anterior wall, medial wall and inferior wall. CONCLUSION: There was obviously overall advantage of using flexible endoscope in postoperative follow-up of MS lesions. Flexible endoscopy can expand the range of observation, and improve the early detection of the recurrent lesion. We recommend flexible endoscope as a routine application.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: During postoperative follow-up, the visible range of maxillary sinus (MS) is limited, even combining 0° and 70° rigid endoscopes together. Flexible endoscope has been used in larynx examinations for a long time, but rarely in nasal cavity and sinus. We aimed to evaluate the application values of rigid and flexible endoscopes for visualization of MS. METHODS: We followed up 70 patients with lesions in MS via both rigid and flexible endoscopes. In addition, we used thin-slice CT image of the sinus to create a MS model and divided it into two parts for 3D printing. The inner surface of the 3D-printed sinus was marked with grid papers of the same size (5 mm × 5 mm), then the visual range under rigid endoscopes with different angle and flexible endoscopes was calculated and analyzed. RESULTS: In clinical follow-up, we found that flexible endoscopy can reach where rigid endoscopy cannot, which is more sensitive than medical imaging. Endoscopes showed the largest observation range of the posterolateral wall, more than half of which can be visualized by 0° endoscope. Almost all of the posterolateral wall can be revealed under 45° endoscope, 70° endoscope and flexible endoscope. The visual range of each wall under flexible endoscope is generally greater than that under rigid endoscopes, especially of the anterior wall, medial wall and inferior wall. CONCLUSION: There was obviously overall advantage of using flexible endoscope in postoperative follow-up of MS lesions. Flexible endoscopy can expand the range of observation, and improve the early detection of the recurrent lesion. We recommend flexible endoscope as a routine application.

Key concepts: Endoscope, Endoscopy, Medicine, Sinus (botany), 3d printed, Surgery, Endoscopic surgery, Visualization

Related papers

Back to paper searchBrowse research topicsOriginal source
Flexible endoscopy in the visualization of 3D-printed maxillary sinus and clinical application — Research Paper | ScholarLens