2022Otology & NeurotologyOpen access

Promontory Electrocochleography Recordings to Predict Speech-Perception Performance in Cochlear Implant Recipients

Amit Walia, Matthew Shew, David S. Lee, Shannon M. Lefler, Dorina Kallogjeri, Cameron C. Wick, Nedim Durakovic, Douglas C. Fitzpatrick, Amanda J. Ortmann, Jacques A. Herzog, Craig A. Buchman

Open full text 26 citations

Abstract

OBJECTIVE: 1) To determine the relationship of electrocochleography (ECochG) responses measured on the promontory with responses measured at the round window (RW) and various intracochlear sites. 2) To evaluate if promontory ECochG responses correlate with postoperative speech-perception performance using the cochlear implant (CI). STUDY DESIGN: Prospective cohort study. SETTING: Tertiary referral center. PATIENTS AND INTERVENTIONS: Ninety-six adult CI recipients with no cochlear malformations or previous otologic surgery. MAIN OUTCOME MEASURES: Acoustically evoked ECochG responses were measured intraoperatively at both extracochlear and intracochlear locations. ECochG total response (ECochG-TR), a measure of residual cochlear function, was calculated by summing the fast Fourier transformation amplitudes in response to 250-Hz to 2-kHz acoustic stimuli. Speech-perception performance was measured at 3 months. RESULTS: There were strong linear correlations for promontory ECochG-TR with the ECochG-TRs measured at the RW ( r = 0.95), just inside scala tympani ( r = 0.91), and after full insertion ( r = 0.83). For an individual subject, the morphology of the ECochG response was similar in character across all positions; however, the response amplitude increased from promontory to RW (~1.6-fold) to just inside scala tympani (~2.6-fold), with the largest response at full insertion (~13.1-fold). Promontory ECochG-TR independently explained 51.8% of the variability ( r2 ) in consonant-nucleus-consonant at 3 months. CONCLUSIONS: Promontory ECochG recordings are strongly correlated with responses previously recorded at extracochlear and intracochlear sites and explain a substantial portion of the variability in CI performance. These findings are a critical step in supporting translation of transtympanic ECochG into the clinic preoperatively to help predict postoperative CI performance.

About this research paper

What this paper is about

OBJECTIVE: 1) To determine the relationship of electrocochleography (ECochG) responses measured on the promontory with responses measured at the round window (RW) and various intracochlear sites. 2) To evaluate if promontory ECochG responses correlate with postoperative speech-perception performance using the cochlear implant (CI). STUDY DESIGN: Prospective cohort study. SETTING: Tertiary referral center. PATIENTS AND INTERVENTIONS: Ninety-six adult CI recipients with no cochlear malformations or previous otologic surgery. MAIN OUTCOME MEASURES: Acoustically evoked ECochG responses were measured intraoperatively at both extracochlear and intracochlear locations. ECochG total response (ECochG-TR), a measure of residual cochlear function, was calculated by summing the fast Fourier transformation amplitudes in response to 250-Hz to 2-kHz acoustic stimuli. Speech-perception performance was measured at 3 months. RESULTS: There were strong linear correlations for promontory ECochG-TR with the ECochG-TRs measured at the RW ( r = 0.95), just inside scala tympani ( r = 0.91), and after full insertion ( r = 0.83). For an individual subject, the morphology of the ECochG response was similar in character across all positions; however, the response amplitude increased from promontory to RW (~1.6-fold) to just inside scala tympani (~2.6-fold), with the largest response at full insertion (~13.1-fold). Promontory ECochG-TR independently explained 51.8% of the variability ( r2 ) in consonant-nucleus-consonant at 3 months. CONCLUSIONS: Promontory ECochG recordings are strongly correlated with responses previously recorded at extracochlear and intracochlear sites and explain a substantial portion of the variability in CI performance. These findings are a critical step in supporting translation of transtympanic ECochG into the clinic preoperatively to help predict postoperative CI performance.

Why it matters

OpenAlex reports 26 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: 1) To determine the relationship of electrocochleography (ECochG) responses measured on the promontory with responses measured at the round window (RW) and various intracochlear sites. 2) To evaluate if promontory ECochG responses correlate with postoperative speech-perception performance using the cochlear implant (CI). STUDY DESIGN: Prospective cohort study. SETTING: Tertiary referral center. PATIENTS AND INTERVENTIONS: Ninety-six adult CI recipients with no cochlear malformations or previous otologic surgery. MAIN OUTCOME MEASURES: Acoustically evoked ECochG responses were measured intraoperatively at both extracochlear and intracochlear locations. ECochG total response (ECochG-TR), a measure of residual cochlear function, was calculated by summing the fast Fourier transformation amplitudes in response to 250-Hz to 2-kHz acoustic stimuli. Speech-perception performance was measured at 3 months. RESULTS: There were strong linear correlations for promontory ECochG-TR with the ECochG-TRs measured at the RW ( r = 0.95), just inside scala tympani ( r = 0.91), and after full insertion ( r = 0.83). For an individual subject, the morphology of the ECochG response was similar in character across all positions; however, the response amplitude increased from promontory to RW (~1.6-fold) to just inside scala tympani (~2.6-fold), with the largest response at full insertion (~13.1-fold). Promontory ECochG-TR independently explained 51.8% of the variability ( r2 ) in consonant-nucleus-consonant at 3 months. CONCLUSIONS: Promontory ECochG recordings are strongly correlated with responses previously recorded at extracochlear and intracochlear sites and explain a substantial portion of the variability in CI performance. These findings are a critical step in supporting translation of transtympanic ECochG into the clinic preoperatively to help predict postoperative CI performance.

Key concepts: Promontory, Electrocochleography, Medicine, Audiology, Cochlear implant, Cochlea, Hearing loss, Archaeology

Related papers

Back to paper searchBrowse research topicsOriginal source
Promontory Electrocochleography Recordings to Predict Speech-Perception Performance in Cochlear Implant Recipients — Research Paper | ScholarLens