Partial Discharge Pulse Propagation in Coaxial Cable
T. Juntasorn, Phop Chancharoensook, Norasage Pattanadech
Abstract
T. Juntasorn, Phop Chancharoensook, Norasage Pattanadech
Abstract
In the past, Coaxial cable was the signal cable used to transfer computer data. However, coaxial cables are now being modified for use in the high voltage coaxial cables to increase the security of power transmission in various areas. In addition to increased security, there is also an issue of stability maintenance and many perspectives as well. Because the cable that used to be utilized is still insulated. Therefore, Partial Discharge (PD) can still happen in the electrical system. This paper presents the PD propagation within the coaxial cable simulated via PSCAD/EMTDC program and carried out with RG-58 coaxial cable in a laboratory by testing the propagation of the PD pulse according to the conditions of different cable distances. From the experiment, the calculations will be reversed by considering on the differences of the time manner that PD pulse flows on the cable. The time reference point that the research studied has 2 points which are Peak to peak and Time of arrival(TOA). The comparison between simulation and experiment indicated the similar results with slight discrepancies caused by factors that can be accepted. TOA has smaller errors comparing with the peak to peak point showing that PD pulse flowing on the cable is attenuation and dispersion to the tailing wave part. That's the reason using Peak to Peak is a time reference point that has more errors. A thorough study of PD propagation is useful for in-depth analysis to locate the PD source accurately. As a result, the defect will be resolved on the spot.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
In the past, Coaxial cable was the signal cable used to transfer computer data. However, coaxial cables are now being modified for use in the high voltage coaxial cables to increase the security of power transmission in various areas. In addition to increased security, there is also an issue of stability maintenance and many perspectives as well. Because the cable that used to be utilized is still insulated. Therefore, Partial Discharge (PD) can still happen in the electrical system. This paper presents the PD propagation within the coaxial cable simulated via PSCAD/EMTDC program and carried out with RG-58 coaxial cable in a laboratory by testing the propagation of the PD pulse according to the conditions of different cable distances. From the experiment, the calculations will be reversed by considering on the differences of the time manner that PD pulse flows on the cable. The time reference point that the research studied has 2 points which are Peak to peak and Time of arrival(TOA). The comparison between simulation and experiment indicated the similar results with slight discrepancies caused by factors that can be accepted. TOA has smaller errors comparing with the peak to peak point showing that PD pulse flowing on the cable is attenuation and dispersion to the tailing wave part. That's the reason using Peak to Peak is a time reference point that has more errors. A thorough study of PD propagation is useful for in-depth analysis to locate the PD source accurately. As a result, the defect will be resolved on the spot.
Key concepts: Coaxial cable, Coaxial, Partial discharge, Attenuation, Pulse (music), Dispersion (optics), SIGNAL (programming language), Acoustics