Utility of pulse-oximetry screening in newborns with nonductus-dependent cyanotic congenital heart defects
Balaji Arvind, Anitá Saxena, Sivasubramanian Ramakrishnan
Abstract
Balaji Arvind, Anitá Saxena, Sivasubramanian Ramakrishnan
Abstract
Objectives: We aimed to compare the performance of pulse-oximetry screening in detecting nonductus-dependent cyanotic congenital heart defects (CCHDs). Methods: In a prospective cross-sectional study, we recorded post ductal saturation of neonates (<48 h old) born at a community hospital in northern India. Subsequently, all underwent clinical examination and echocardiogram by a trained cardiologist. A saturation <95% was considered a "failed" screen. Results: Ten neonates were identified to have nonductus-dependent CCHD on echocardiogram, five of whom had passed pulse-oximetry screen. This translated to a sensitivity of 50% (95% confidence interval [CI] 23.7%-76.3%) and a positive predictive value of 0.08 (95% CI 0.03-0.2), both of which were significantly less compared to that in ductus-dependent congenital heart defect. Conclusions: Up to half of the nonductus-dependent CCHD may be missed if screened only using pulse oximetry. Parents should not be reassured regarding the absence of CCHD only based on a "pass" in pulse-oximetry screening.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objectives: We aimed to compare the performance of pulse-oximetry screening in detecting nonductus-dependent cyanotic congenital heart defects (CCHDs). Methods: In a prospective cross-sectional study, we recorded post ductal saturation of neonates (<48 h old) born at a community hospital in northern India. Subsequently, all underwent clinical examination and echocardiogram by a trained cardiologist. A saturation <95% was considered a "failed" screen. Results: Ten neonates were identified to have nonductus-dependent CCHD on echocardiogram, five of whom had passed pulse-oximetry screen. This translated to a sensitivity of 50% (95% confidence interval [CI] 23.7%-76.3%) and a positive predictive value of 0.08 (95% CI 0.03-0.2), both of which were significantly less compared to that in ductus-dependent congenital heart defect. Conclusions: Up to half of the nonductus-dependent CCHD may be missed if screened only using pulse oximetry. Parents should not be reassured regarding the absence of CCHD only based on a "pass" in pulse-oximetry screening.
Key concepts: Pulse oximetry, Medicine, Heart defect, Cardiology, Internal medicine, Heart disease, Anesthesia