2022Unpublished venueRequires access

Design and Implementation of A High-Precision Low-Power Instrumentation Amplifier

Xueting Zhao, Xinpeng Xing, Gaofeng Luan, Zhengzhong Wu, Zhihua Wang

Open publisher page 4 citations

Abstract

This paper presents a high-precision and low-power two-stage miller-compensated instrumentation amplifier for sensor readout circuits. Folded-cascode structure with complementary input differential pairs and translinear-loop-based class AB circuit are adopted as the amplifier first and second stages respectively, to achieve rail-to-rail input and output ranges. The presented instrumentation amplifier is implemented in a 0.18μm BCD technology. Measurement results show that with a load of 100pF and 100kΩ, the presented amplifier achieves 79. 79dB gain, 1. 35MHz gain-bandwidth product (GBW) and 92. 3dB power supply rejection ratio (PSRR). The measured amplifier gain error is 0.11%; and its input offset voltage is 0. 3mV. This amplifier totally consumes 0. 19mW power from a 3V supply voltage.

About this research paper

What this paper is about

This paper presents a high-precision and low-power two-stage miller-compensated instrumentation amplifier for sensor readout circuits. Folded-cascode structure with complementary input differential pairs and translinear-loop-based class AB circuit are adopted as the amplifier first and second stages respectively, to achieve rail-to-rail input and output ranges. The presented instrumentation amplifier is implemented in a 0.18μm BCD technology. Measurement results show that with a load of 100pF and 100kΩ, the presented amplifier achieves 79. 79dB gain, 1. 35MHz gain-bandwidth product (GBW) and 92. 3dB power supply rejection ratio (PSRR). The measured amplifier gain error is 0.11%; and its input offset voltage is 0. 3mV. This amplifier totally consumes 0. 19mW power from a 3V supply voltage.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper presents a high-precision and low-power two-stage miller-compensated instrumentation amplifier for sensor readout circuits. Folded-cascode structure with complementary input differential pairs and translinear-loop-based class AB circuit are adopted as the amplifier first and second stages respectively, to achieve rail-to-rail input and output ranges. The presented instrumentation amplifier is implemented in a 0.18μm BCD technology. Measurement results show that with a load of 100pF and 100kΩ, the presented amplifier achieves 79. 79dB gain, 1. 35MHz gain-bandwidth product (GBW) and 92. 3dB power supply rejection ratio (PSRR). The measured amplifier gain error is 0.11%; and its input offset voltage is 0. 3mV. This amplifier totally consumes 0. 19mW power from a 3V supply voltage.

Key concepts: Power supply rejection ratio, Instrumentation amplifier, Direct-coupled amplifier, Operational transconductance amplifier, Fully differential amplifier, Operational amplifier, RF power amplifier, Input offset voltage

Related papers

Back to paper searchBrowse research topicsOriginal source
Design and Implementation of A High-Precision Low-Power Instrumentation Amplifier — Research Paper | ScholarLens