2022•Scientific ReportsOpen access

A new method to quantify left ventricular mass by 2D echocardiography

Charlotte Burup Kristensen, Katrine Aagaard Myhr, Frederik Fasth Grund, Niels Grove Vejlstrup, Christian Hassager, Raj K. Mattu, Rasmus Møgelvang

Open full text 13 citations

Abstract

Increased left ventricular mass (LVM) is a strong independent predictor for adverse cardiovascular events, but conventional echocardiographic methods are limited by poor reproducibility and accuracy. We developed a novel method based on adding the mean wall thickness from the parasternal short axis view, to the left ventricular end-diastolic volume acquired using the biplane model of discs. The participants (n = 85) had various left ventricular geometries and were assessed using echocardiography followed immediately by cardiac magnetic resonance, as reference. We compared our novel two-dimensional (2D) method to various conventional one-dimensional (1D) and other 2D methods as well as the three-dimensional (3D) method. Our novel method had better reproducibility in intra-examiner [coefficients of variation (CV) 9% vs. 11-14%] and inter-examiner analysis (CV 9% vs. 10-20%). Accuracy was similar to the 3D method (mean difference ± 95% limits of agreement, CV): Novel: 2 ± 50 g, 15% vs. 3D: 2 ± 51 g, 16%; and better than the "linear" 1D method by Devereux (7 ± 76 g, 23%). Our novel method is simple, has considerable better reproducibility and accuracy than conventional "linear" 1D methods, and similar accuracy as the 3D-method. As the biplane model forms part of the standard echocardiographic protocol, it does not require specific training and provides a supplement to the modern echocardiographic report.

Open-access reader

About this research paper

What this paper is about

Increased left ventricular mass (LVM) is a strong independent predictor for adverse cardiovascular events, but conventional echocardiographic methods are limited by poor reproducibility and accuracy. We developed a novel method based on adding the mean wall thickness from the parasternal short axis view, to the left ventricular end-diastolic volume acquired using the biplane model of discs. The participants (n = 85) had various left ventricular geometries and were assessed using echocardiography followed immediately by cardiac magnetic resonance, as reference. We compared our novel two-dimensional (2D) method to various conventional one-dimensional (1D) and other 2D methods as well as the three-dimensional (3D) method. Our novel method had better reproducibility in intra-examiner [coefficients of variation (CV) 9% vs. 11-14%] and inter-examiner analysis (CV 9% vs. 10-20%). Accuracy was similar to the 3D method (mean difference ± 95% limits of agreement, CV): Novel: 2 ± 50 g, 15% vs. 3D: 2 ± 51 g, 16%; and better than the "linear" 1D method by Devereux (7 ± 76 g, 23%). Our novel method is simple, has considerable better reproducibility and accuracy than conventional "linear" 1D methods, and similar accuracy as the 3D-method. As the biplane model forms part of the standard echocardiographic protocol, it does not require specific training and provides a supplement to the modern echocardiographic report.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Increased left ventricular mass (LVM) is a strong independent predictor for adverse cardiovascular events, but conventional echocardiographic methods are limited by poor reproducibility and accuracy. We developed a novel method based on adding the mean wall thickness from the parasternal short axis view, to the left ventricular end-diastolic volume acquired using the biplane model of discs. The participants (n = 85) had various left ventricular geometries and were assessed using echocardiography followed immediately by cardiac magnetic resonance, as reference. We compared our novel two-dimensional (2D) method to various conventional one-dimensional (1D) and other 2D methods as well as the three-dimensional (3D) method. Our novel method had better reproducibility in intra-examiner [coefficients of variation (CV) 9% vs. 11-14%] and inter-examiner analysis (CV 9% vs. 10-20%). Accuracy was similar to the 3D method (mean difference ± 95% limits of agreement, CV): Novel: 2 ± 50 g, 15% vs. 3D: 2 ± 51 g, 16%; and better than the "linear" 1D method by Devereux (7 ± 76 g, 23%). Our novel method is simple, has considerable better reproducibility and accuracy than conventional "linear" 1D methods, and similar accuracy as the 3D-method. As the biplane model forms part of the standard echocardiographic protocol, it does not require specific training and provides a supplement to the modern echocardiographic report.

Key concepts: Cardiology, Internal medicine, Medicine, Ventricular function

Related papers

Back to paper searchBrowse research topicsOriginal source
A new method to quantify left ventricular mass by 2D echocardiography — Research Paper | ScholarLens