2022Mutation Research/Genetic Toxicology and Environmental MutagenesisOpen access

A comparison of the lowest effective concentration in culture media for detection of chromosomal damage in vitro and in blood or plasma for detection of micronuclei in vivo

David Kirkland, James Whitwell, Robert Smith, Kiyohiro Hashimoto, Zhiying Ji, Julia Kenny, Naoki Koyama, David P. Lovell, Hans‐Jörg Martus, Krista Meurer, Daniel J. Roberts, Akira Takeiri, Yoshifumi Uno, Bas‐jan van der Leede, Paul A. White, Andreas Zeller

Open full text 2 citations

Abstract

It is often assumed that genotoxic substances will be detected more easily by using in vitro rather than in vivo genotoxicity tests since higher concentrations, more cytotoxicity and static exposures can be achieved. However, there is a paucity of data demonstrating whether genotoxic substances are detected at lower concentrations in cell culture in vitro than can be reached in the blood of animals treated in vivo. To investigate this issue, we compared the lowest concentration required for induction of chromosomal damage in vitro (lowest observed effective concentration, or LOEC) with the concentration of the test substance in blood at the lowest dose required for biologically relevant induction of micronuclei in vivo (lowest observed effective dose, or LOED). In total, 83 substances were found for which the LOED could be identified or estimated, where concentrations in blood and micronucleus data were available via the same route of administration in the same species, and in vitro chromosomal damage data were available. 39.8 % of substances were positive in vivo at blood concentrations that were lower than the LOEC in vitro, 22.9 % were positive at similar concentrations, and 37.3 % of substances were positive in vivo at higher concentrations. Distribution analysis showed a very wide scatter of > 6 orders of magnitude across these 3 categories. When mode of action was evaluated, the distribution of clastogens and aneugens across the 3 categories was very similar. Thus, the ability to detect induction of micronuclei in bone marrow in vivo regardless of the mechanism for micronucleus induction, is clearly not solely determined by the concentration of test substance which induced chromosomal damage in vitro.

Open-access reader

About this research paper

What this paper is about

It is often assumed that genotoxic substances will be detected more easily by using in vitro rather than in vivo genotoxicity tests since higher concentrations, more cytotoxicity and static exposures can be achieved. However, there is a paucity of data demonstrating whether genotoxic substances are detected at lower concentrations in cell culture in vitro than can be reached in the blood of animals treated in vivo. To investigate this issue, we compared the lowest concentration required for induction of chromosomal damage in vitro (lowest observed effective concentration, or LOEC) with the concentration of the test substance in blood at the lowest dose required for biologically relevant induction of micronuclei in vivo (lowest observed effective dose, or LOED). In total, 83 substances were found for which the LOED could be identified or estimated, where concentrations in blood and micronucleus data were available via the same route of administration in the same species, and in vitro chromosomal damage data were available. 39.8 % of substances were positive in vivo at blood concentrations that were lower than the LOEC in vitro, 22.9 % were positive at similar concentrations, and 37.3 % of substances were positive in vivo at higher concentrations. Distribution analysis showed a very wide scatter of > 6 orders of magnitude across these 3 categories. When mode of action was evaluated, the distribution of clastogens and aneugens across the 3 categories was very similar. Thus, the ability to detect induction of micronuclei in bone marrow in vivo regardless of the mechanism for micronucleus induction, is clearly not solely determined by the concentration of test substance which induced chromosomal damage in vitro.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

It is often assumed that genotoxic substances will be detected more easily by using in vitro rather than in vivo genotoxicity tests since higher concentrations, more cytotoxicity and static exposures can be achieved. However, there is a paucity of data demonstrating whether genotoxic substances are detected at lower concentrations in cell culture in vitro than can be reached in the blood of animals treated in vivo. To investigate this issue, we compared the lowest concentration required for induction of chromosomal damage in vitro (lowest observed effective concentration, or LOEC) with the concentration of the test substance in blood at the lowest dose required for biologically relevant induction of micronuclei in vivo (lowest observed effective dose, or LOED). In total, 83 substances were found for which the LOED could be identified or estimated, where concentrations in blood and micronucleus data were available via the same route of administration in the same species, and in vitro chromosomal damage data were available. 39.8 % of substances were positive in vivo at blood concentrations that were lower than the LOEC in vitro, 22.9 % were positive at similar concentrations, and 37.3 % of substances were positive in vivo at higher concentrations. Distribution analysis showed a very wide scatter of > 6 orders of magnitude across these 3 categories. When mode of action was evaluated, the distribution of clastogens and aneugens across the 3 categories was very similar. Thus, the ability to detect induction of micronuclei in bone marrow in vivo regardless of the mechanism for micronucleus induction, is clearly not solely determined by the concentration of test substance which induced chromosomal damage in vitro.

Key concepts: Micronucleus test, In vivo, Genotoxicity, Micronucleus, Clastogen, In vitro, Pharmacology, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
A comparison of the lowest effective concentration in culture media for detection of chromosomal damage in vitro and in blood or plasma for detection of micronuclei in vivo — Research Paper | ScholarLens