Seismic Response Control of High-Rise Mass Varied Structures Using Linear Fluid Viscous Damper
Arun Kumar G S, Jagadish G Kori
Abstract
Open-access reader
Arun Kumar G S, Jagadish G Kori
Abstract
Open-access reader
Abstract: Seismic event induces undesirable motion in buildings, energy dissipation systems in civil engineering are indeed needed. There is a mix of structures with passive energy dissipation supplied by Fluid Viscous Dampers systems (FVD). This technology is increasingly being utilized to improve seismic protection for both existing and new structures. The findings of the FVD systems are investigated in order to compare the structural response with and without this device of energy dissipation compared for low and high rise structures, the damper installed at different storey and varying the coefficient of damping (Cd) has been focused in this paper which provides an insight when the variation of Cd and its locations,. The findings of the FVD's impressive ability to increase the structure's dissipative capabilities without increasing its stiffness. In the case of high rise FVD performance has been evaluated through the top storey displacements which will allow for a conclusion. Keywords: Coefficient of Damping, Fluid Viscous Damper, High Rise Buildings, Seismic Response, Tall Structure
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Abstract: Seismic event induces undesirable motion in buildings, energy dissipation systems in civil engineering are indeed needed. There is a mix of structures with passive energy dissipation supplied by Fluid Viscous Dampers systems (FVD). This technology is increasingly being utilized to improve seismic protection for both existing and new structures. The findings of the FVD systems are investigated in order to compare the structural response with and without this device of energy dissipation compared for low and high rise structures, the damper installed at different storey and varying the coefficient of damping (Cd) has been focused in this paper which provides an insight when the variation of Cd and its locations,. The findings of the FVD's impressive ability to increase the structure's dissipative capabilities without increasing its stiffness. In the case of high rise FVD performance has been evaluated through the top storey displacements which will allow for a conclusion. Keywords: Coefficient of Damping, Fluid Viscous Damper, High Rise Buildings, Seismic Response, Tall Structure
Key concepts: Dissipation, Damper, Dissipative system, Tuned mass damper, Structural engineering, Stiffness, Energy (signal processing), Geology