Surface roughness and cyclic fatigue resistance of reciprocating and novel rotary instruments after use in curved root canals
Balić Merima, Ivona Bago, Dubravka Milovanović, Gianluca Plotino, Ivica Anić
Abstract
Balić Merima, Ivona Bago, Dubravka Milovanović, Gianluca Plotino, Ivica Anić
Abstract
This study evaluated surface wear and resistance to fracture of reciprocating and novel rotary instruments after use in curved canals. Twenty new instruments (n = 5/each group): Reciproc Blue, WaveOne Gold, XP-endo Shaper (XPS) and TruNatomy were used twice for the instrumentation of simulated curved canals in plastic blocks. The instrumentation was performed according to the manufacturer's instructions at body temperature. Surface roughness was evaluated, using a profilometer, before instrumentation and twice after the instrumentation. Instruments were, then, subjected to a cyclic fatigue test to evaluate the time to failure. Differences were assessed using ANOVA and post hoc tests (α = 0.05). The XPS instruments showed significantly higher values of roughness compared with TruNatomy at every stage, especially after the second use (p < 0.008). Reciprocating instruments showed superior cyclic fatigue resistance compared with novel rotary instruments (p < 0.05). TruNatomy showed minimal surface roughness, and XPS exhibited significantly higher surface roughness.
OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
This study evaluated surface wear and resistance to fracture of reciprocating and novel rotary instruments after use in curved canals. Twenty new instruments (n = 5/each group): Reciproc Blue, WaveOne Gold, XP-endo Shaper (XPS) and TruNatomy were used twice for the instrumentation of simulated curved canals in plastic blocks. The instrumentation was performed according to the manufacturer's instructions at body temperature. Surface roughness was evaluated, using a profilometer, before instrumentation and twice after the instrumentation. Instruments were, then, subjected to a cyclic fatigue test to evaluate the time to failure. Differences were assessed using ANOVA and post hoc tests (α = 0.05). The XPS instruments showed significantly higher values of roughness compared with TruNatomy at every stage, especially after the second use (p < 0.008). Reciprocating instruments showed superior cyclic fatigue resistance compared with novel rotary instruments (p < 0.05). TruNatomy showed minimal surface roughness, and XPS exhibited significantly higher surface roughness.
Key concepts: Reciprocating motion, Profilometer, Instrumentation (computer programming), Materials science, Surface roughness, Surface finish, Post hoc, X-ray photoelectron spectroscopy