2022Russian Journal of ElectrochemistryRequires access

Nanoparticles Application in the Determination of Uric Acid, Ascorbic Acid, and Dopamine

Charlton van der Horst, Vernon Somerset

Open publisher page 11 citations

Abstract

Abstract This review describes the application of nanomaterials for the individual and simultaneous detection of dopamine (DA), uric acid (UA), and ascorbic acid (AA). Scientists have worked over the past years to modify electrode surfaces by using different nanomaterials to improve the selectivity, limits of detection, and sensitivity of sensors. In this review, the authors have briefly discussed the nanomaterials that were extensively applied in the construction and modification of working electrode surfaces for the detection of DA, UA, and AA. The electrochemical detection of DA, UA, and AA were categorized into three main sections including the detection in the presence of interferents, individual detection and the simultaneous detection of these molecules. For the individual detection of DA, UA, and AA the lowest detection limit was achieved by a Au/PDDA–rGO sensor in the detection of UA in urine samples. A detection limit of 0.0008 µM with a wide linear range of 0.25 to 150 µM was recorded. In the simultaneous detection of DA, UA, and AA in serum and urine samples, a Fe3O4–SnO2–Gr sensor gives the lowest detection limits (0.0071 µM for DA, 0.005 µM for UA, 0.0062 µM for AA) with good linear range (0.02 to 2.8 µM for DA, 0.015 to 2.40 µM for UA, 0.1 to 23 µM for AA). In the case of the simultaneous detection of DA and UA in serum and urine samples, the lowest detection limits were obtained by Au–Pt sensor. The detection limits (0.006 µM for DA, 0.038 µM for UA) with good linear range (0.1 to 400 µM for DA, 1 to 1000 µM for UA).

About this research paper

What this paper is about

Abstract This review describes the application of nanomaterials for the individual and simultaneous detection of dopamine (DA), uric acid (UA), and ascorbic acid (AA). Scientists have worked over the past years to modify electrode surfaces by using different nanomaterials to improve the selectivity, limits of detection, and sensitivity of sensors. In this review, the authors have briefly discussed the nanomaterials that were extensively applied in the construction and modification of working electrode surfaces for the detection of DA, UA, and AA. The electrochemical detection of DA, UA, and AA were categorized into three main sections including the detection in the presence of interferents, individual detection and the simultaneous detection of these molecules. For the individual detection of DA, UA, and AA the lowest detection limit was achieved by a Au/PDDA–rGO sensor in the detection of UA in urine samples. A detection limit of 0.0008 µM with a wide linear range of 0.25 to 150 µM was recorded. In the simultaneous detection of DA, UA, and AA in serum and urine samples, a Fe3O4–SnO2–Gr sensor gives the lowest detection limits (0.0071 µM for DA, 0.005 µM for UA, 0.0062 µM for AA) with good linear range (0.02 to 2.8 µM for DA, 0.015 to 2.40 µM for UA, 0.1 to 23 µM for AA). In the case of the simultaneous detection of DA and UA in serum and urine samples, the lowest detection limits were obtained by Au–Pt sensor. The detection limits (0.006 µM for DA, 0.038 µM for UA) with good linear range (0.1 to 400 µM for DA, 1 to 1000 µM for UA).

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract This review describes the application of nanomaterials for the individual and simultaneous detection of dopamine (DA), uric acid (UA), and ascorbic acid (AA). Scientists have worked over the past years to modify electrode surfaces by using different nanomaterials to improve the selectivity, limits of detection, and sensitivity of sensors. In this review, the authors have briefly discussed the nanomaterials that were extensively applied in the construction and modification of working electrode surfaces for the detection of DA, UA, and AA. The electrochemical detection of DA, UA, and AA were categorized into three main sections including the detection in the presence of interferents, individual detection and the simultaneous detection of these molecules. For the individual detection of DA, UA, and AA the lowest detection limit was achieved by a Au/PDDA–rGO sensor in the detection of UA in urine samples. A detection limit of 0.0008 µM with a wide linear range of 0.25 to 150 µM was recorded. In the simultaneous detection of DA, UA, and AA in serum and urine samples, a Fe3O4–SnO2–Gr sensor gives the lowest detection limits (0.0071 µM for DA, 0.005 µM for UA, 0.0062 µM for AA) with good linear range (0.02 to 2.8 µM for DA, 0.015 to 2.40 µM for UA, 0.1 to 23 µM for AA). In the case of the simultaneous detection of DA and UA in serum and urine samples, the lowest detection limits were obtained by Au–Pt sensor. The detection limits (0.006 µM for DA, 0.038 µM for UA) with good linear range (0.1 to 400 µM for DA, 1 to 1000 µM for UA).

Key concepts: Detection limit, Ascorbic acid, Chemistry, Linear range, Chromatography, Nanomaterials, Uric acid, Urine

Related papers

Back to paper searchBrowse research topicsOriginal source