DC corona discharge from a wire particle floated with a micro-gap in parallel plate electrodes

Y. Kudo, Toshiki Sugimoto, Y. Higashiyama

Open publisher page 1 citations

Abstract

A conductive particles existing in a high electric field could deteriorate the performance of insulating system due to electric discharge via the particles. In the case when the particles are around of the high voltage electrode, the position of the particle affects the aspect of the electric discharge. Corona onset and breakdown voltage from a metallic wire particle were investigated under the condition of the wire particle with a length of ranging from 6 to 12 mm and a diameter of 0.25 mm inserted a parallel plate electrode with a spacing of 20 mm or 30 mm. When the particle was close to the negative electrode, corona discharge occurred stably and the corona onset voltage was increased with the gap length bellow 0.8 mm. In contrast, when the particle was close to the positive electrode, breakdown always occurred without stable corona discharge. At the middle region between the electrodes, the corona onset voltage kept almost constant.

About this research paper

What this paper is about

A conductive particles existing in a high electric field could deteriorate the performance of insulating system due to electric discharge via the particles. In the case when the particles are around of the high voltage electrode, the position of the particle affects the aspect of the electric discharge. Corona onset and breakdown voltage from a metallic wire particle were investigated under the condition of the wire particle with a length of ranging from 6 to 12 mm and a diameter of 0.25 mm inserted a parallel plate electrode with a spacing of 20 mm or 30 mm. When the particle was close to the negative electrode, corona discharge occurred stably and the corona onset voltage was increased with the gap length bellow 0.8 mm. In contrast, when the particle was close to the positive electrode, breakdown always occurred without stable corona discharge. At the middle region between the electrodes, the corona onset voltage kept almost constant.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A conductive particles existing in a high electric field could deteriorate the performance of insulating system due to electric discharge via the particles. In the case when the particles are around of the high voltage electrode, the position of the particle affects the aspect of the electric discharge. Corona onset and breakdown voltage from a metallic wire particle were investigated under the condition of the wire particle with a length of ranging from 6 to 12 mm and a diameter of 0.25 mm inserted a parallel plate electrode with a spacing of 20 mm or 30 mm. When the particle was close to the negative electrode, corona discharge occurred stably and the corona onset voltage was increased with the gap length bellow 0.8 mm. In contrast, when the particle was close to the positive electrode, breakdown always occurred without stable corona discharge. At the middle region between the electrodes, the corona onset voltage kept almost constant.

Key concepts: Corona discharge, Corona ring, Electrode, Materials science, Brush discharge, Electric field, Plate electrode, Corona (planetary geology)

Related papers

Back to paper searchBrowse research topicsOriginal source
DC corona discharge from a wire particle floated with a micro-gap in parallel plate electrodes — Research Paper | ScholarLens