Transducer Array-Based Photoacoustic Tomography: 2D, 3D, and 4-D Photoacoustic Imaging
Huabei Jiang
Abstract
Huabei Jiang
Abstract
In this chapter, we describe a transducer array-based photoacoustic tomography (PAT) system and demonstrate its ability for 2D, 3D, and 4-D photoacoustic imaging of biological tissue. Figures 4.1a and 4.1b present the photograph of an array-based PAT system. As shown in Figure 4.1a, a tunable Ti:Sapphire laser (part A) is used to provide 690 to 950 nm near-infrared (NIR) laser pulses with a pulse width of 8 to 25 ns and a repetition rate of 10 Hz. The photoacoustic signals generated by the laser are received by a full-ring array with 5 MHz frequency transducers (part B). Preamplifiers/amplifiers (part C) amplify the signals from the transducers and deliver the amplified signals to the A/D boards (part D), which are controlled by the computer (part E). The three key components of the system including the tunable laser, ultrasound transducer array, and data acquisition system are discussed in detail in Sections 4.1 to 4.3 below.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
In this chapter, we describe a transducer array-based photoacoustic tomography (PAT) system and demonstrate its ability for 2D, 3D, and 4-D photoacoustic imaging of biological tissue. Figures 4.1a and 4.1b present the photograph of an array-based PAT system. As shown in Figure 4.1a, a tunable Ti:Sapphire laser (part A) is used to provide 690 to 950 nm near-infrared (NIR) laser pulses with a pulse width of 8 to 25 ns and a repetition rate of 10 Hz. The photoacoustic signals generated by the laser are received by a full-ring array with 5 MHz frequency transducers (part B). Preamplifiers/amplifiers (part C) amplify the signals from the transducers and deliver the amplified signals to the A/D boards (part D), which are controlled by the computer (part E). The three key components of the system including the tunable laser, ultrasound transducer array, and data acquisition system are discussed in detail in Sections 4.1 to 4.3 below.
Key concepts: Photoacoustic imaging in biomedicine, Photoacoustic tomography, Transducer, Tomography, Materials science, Photoacoustic Doppler effect, Acoustics, Biomedical engineering