2017Unpublished venueOpen access

Effectiveness of distributed temperature measurements for early detection of piping in river embankments

Silvia Bersan, André Koelewijn, Paolo Simonini

Open full text 4 citations

Abstract

Abstract. Internal erosion is the cause of a significant percentage of failure and incidents involving both dams and river embankments in many countries. In the past 20 years the use of fibre-optic Distributed Temperature Sensing (DTS) in dams has proved to be an effective tool for detection of leakages and internal erosion. This work investigates the effectiveness of DTS for dike monitoring, focusing on early detection of backward erosion piping, a mechanism that affects the foundation layer of structures resting on permeable, sandy soils. The paper presents data from a piping test performed on a large-scale experimental dike equipped with a DTS system together with a large number of accompanying sensors. The effect of seepage and piping on the temperature field is analysed, eventually identifying the processes that cause the onset of thermal anomalies around piping channels and thus enable their early detection. Making use of dimensional analysis, the factors that influence that thermal response of a dike foundation are identified. Eventually some tools are provided that can be helpful for the design of monitoring systems and for interpretation of temperature data.

Open-access reader

About this research paper

What this paper is about

Abstract. Internal erosion is the cause of a significant percentage of failure and incidents involving both dams and river embankments in many countries. In the past 20 years the use of fibre-optic Distributed Temperature Sensing (DTS) in dams has proved to be an effective tool for detection of leakages and internal erosion. This work investigates the effectiveness of DTS for dike monitoring, focusing on early detection of backward erosion piping, a mechanism that affects the foundation layer of structures resting on permeable, sandy soils. The paper presents data from a piping test performed on a large-scale experimental dike equipped with a DTS system together with a large number of accompanying sensors. The effect of seepage and piping on the temperature field is analysed, eventually identifying the processes that cause the onset of thermal anomalies around piping channels and thus enable their early detection. Making use of dimensional analysis, the factors that influence that thermal response of a dike foundation are identified. Eventually some tools are provided that can be helpful for the design of monitoring systems and for interpretation of temperature data.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract. Internal erosion is the cause of a significant percentage of failure and incidents involving both dams and river embankments in many countries. In the past 20 years the use of fibre-optic Distributed Temperature Sensing (DTS) in dams has proved to be an effective tool for detection of leakages and internal erosion. This work investigates the effectiveness of DTS for dike monitoring, focusing on early detection of backward erosion piping, a mechanism that affects the foundation layer of structures resting on permeable, sandy soils. The paper presents data from a piping test performed on a large-scale experimental dike equipped with a DTS system together with a large number of accompanying sensors. The effect of seepage and piping on the temperature field is analysed, eventually identifying the processes that cause the onset of thermal anomalies around piping channels and thus enable their early detection. Making use of dimensional analysis, the factors that influence that thermal response of a dike foundation are identified. Eventually some tools are provided that can be helpful for the design of monitoring systems and for interpretation of temperature data.

Key concepts: Piping, Dike, Internal erosion, Foundation (evidence), Erosion, Geotechnical engineering, Environmental science, Work (physics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Effectiveness of distributed temperature measurements for early detection of piping in river embankments — Research Paper | ScholarLens