The performance of the GPSC/MSGC hybrid detector with neon-xenon gas mixtures
L. M. P. Fernandes, D.S.A.P. Freitas, A. Trindade, J.F.C.A. Veloso, C. M. B. Monteiro, L. F. Requicha Ferreira, J.M.F. dos Santos
Abstract
L. M. P. Fernandes, D.S.A.P. Freitas, A. Trindade, J.F.C.A. Veloso, C. M. B. Monteiro, L. F. Requicha Ferreira, J.M.F. dos Santos
Abstract
The performance for x-ray spectrometry of neon-xenon gas proportional scintillation counters using a CsI-coated microstrip plate in direct contact with the scintillation gas as a VUV photosensor is investigated for different neon-xenon mixtures. At best operation conditions, the detector gain can reach values about 50% higher than those achieved with pure xenon filling. The highest gains and the best energy resolutions are achieved for xenon contents around 40%. However, the achieved energy resolutions are similar to those achieved with pure xenon. As in pure xenon and argon-xenon mixture gas-fillings, the detector performance is limited by optical positive feedback resulting from additional scintillation produced in the electron avalanche processes around the MSP-anodes. Best energy resolutions are achieved for positive feedback gains in the range of 1.1 to 1.2. The performance achieved with neon-xenon mixtures is inferior to that achieved with argon-xenon mixtures.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The performance for x-ray spectrometry of neon-xenon gas proportional scintillation counters using a CsI-coated microstrip plate in direct contact with the scintillation gas as a VUV photosensor is investigated for different neon-xenon mixtures. At best operation conditions, the detector gain can reach values about 50% higher than those achieved with pure xenon filling. The highest gains and the best energy resolutions are achieved for xenon contents around 40%. However, the achieved energy resolutions are similar to those achieved with pure xenon. As in pure xenon and argon-xenon mixture gas-fillings, the detector performance is limited by optical positive feedback resulting from additional scintillation produced in the electron avalanche processes around the MSP-anodes. Best energy resolutions are achieved for positive feedback gains in the range of 1.1 to 1.2. The performance achieved with neon-xenon mixtures is inferior to that achieved with argon-xenon mixtures.
Key concepts: Xenon, Neon, Scintillation, Argon, Detector, Noble gas, Materials science, Scintillation counter