20032003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515)Requires access

The performance of the GPSC/MSGC hybrid detector with neon-xenon gas mixtures

L. M. P. Fernandes, D.S.A.P. Freitas, A. Trindade, J.F.C.A. Veloso, C. M. B. Monteiro, L. F. Requicha Ferreira, J.M.F. dos Santos

Open publisher page 0 citations

Abstract

The performance for x-ray spectrometry of neon-xenon gas proportional scintillation counters using a CsI-coated microstrip plate in direct contact with the scintillation gas as a VUV photosensor is investigated for different neon-xenon mixtures. At best operation conditions, the detector gain can reach values about 50% higher than those achieved with pure xenon filling. The highest gains and the best energy resolutions are achieved for xenon contents around 40%. However, the achieved energy resolutions are similar to those achieved with pure xenon. As in pure xenon and argon-xenon mixture gas-fillings, the detector performance is limited by optical positive feedback resulting from additional scintillation produced in the electron avalanche processes around the MSP-anodes. Best energy resolutions are achieved for positive feedback gains in the range of 1.1 to 1.2. The performance achieved with neon-xenon mixtures is inferior to that achieved with argon-xenon mixtures.

About this research paper

What this paper is about

The performance for x-ray spectrometry of neon-xenon gas proportional scintillation counters using a CsI-coated microstrip plate in direct contact with the scintillation gas as a VUV photosensor is investigated for different neon-xenon mixtures. At best operation conditions, the detector gain can reach values about 50% higher than those achieved with pure xenon filling. The highest gains and the best energy resolutions are achieved for xenon contents around 40%. However, the achieved energy resolutions are similar to those achieved with pure xenon. As in pure xenon and argon-xenon mixture gas-fillings, the detector performance is limited by optical positive feedback resulting from additional scintillation produced in the electron avalanche processes around the MSP-anodes. Best energy resolutions are achieved for positive feedback gains in the range of 1.1 to 1.2. The performance achieved with neon-xenon mixtures is inferior to that achieved with argon-xenon mixtures.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The performance for x-ray spectrometry of neon-xenon gas proportional scintillation counters using a CsI-coated microstrip plate in direct contact with the scintillation gas as a VUV photosensor is investigated for different neon-xenon mixtures. At best operation conditions, the detector gain can reach values about 50% higher than those achieved with pure xenon filling. The highest gains and the best energy resolutions are achieved for xenon contents around 40%. However, the achieved energy resolutions are similar to those achieved with pure xenon. As in pure xenon and argon-xenon mixture gas-fillings, the detector performance is limited by optical positive feedback resulting from additional scintillation produced in the electron avalanche processes around the MSP-anodes. Best energy resolutions are achieved for positive feedback gains in the range of 1.1 to 1.2. The performance achieved with neon-xenon mixtures is inferior to that achieved with argon-xenon mixtures.

Key concepts: Xenon, Neon, Scintillation, Argon, Detector, Noble gas, Materials science, Scintillation counter

Related papers

Back to paper searchBrowse research topicsOriginal source
The performance of the GPSC/MSGC hybrid detector with neon-xenon gas mixtures — Research Paper | ScholarLens