2020•Research SquareOpen access

Plantar pressure sensors indicate women to have a significantly higher peak pressure on the hallux, toes, forefoot, and medial of the foot compared to men

Tetsuya Yamamoto, Yuichi Y. Hoshino, Noriyuki Kanzaki, Koji Nukuto, Takahiro Yamashita, Kazuyuki Ibaraki, Kanto Nagai, Kouki Nagamune, Daisuke Araki, Takehiko Matsushita, Ryosuke Kuroda

Open full text 0 citations

Abstract

Abstract Background: Sex-related differences of plantar pressure distribution during activities should be thoroughly inspected as it can help establish treatment and prevention strategies for foot and ankle problems. In-shoe measurement systems are preferable without space and activity restrictions; however, previously reported systems are still heavy and bulky and induce unnatural movement. Therefore, a slim and light plantar pressure sensor was newly developed to detect the effect of sex difference on plantar pressure during standing and walking.Methods: One-hundred healthy adult volunteers (50 women and 50 men) were recruited. Ten plantar pressure sensors were implanted in a 1-mm thick insole, with a total weight of 29 g. Plantar pressure was recorded with 200 Hz during 3 seconds of standing and while walking 10 steps. The maximum loads during standing and walking were analyzed in each sensor, and the results were compared between different areas of the foot in the antero-posterior direction and the medio-lateral direction and between different time points. The movement of the center of pressure (COP) during walking was also evaluated. Results were compared between sexes by converting body mass index (BMI) to 22.Results: The movement of COP was constant for both sexes. In all cases, the maximum load was observed on the medial of the foot. Women had a significantly higher peak pressure on the hallux, toes, forefoot, and medial of the foot compared to men while standing and walking (P < .05).Conclusions: A newly introduced in-shoe plantar pressure sensor demonstrated a typical loading transition pattern of the foot. Furthermore, higher plantar pressure in the forefoot was detected in healthy women as compared to men during standing and walking activities.

Open-access reader

About this research paper

What this paper is about

Abstract Background: Sex-related differences of plantar pressure distribution during activities should be thoroughly inspected as it can help establish treatment and prevention strategies for foot and ankle problems. In-shoe measurement systems are preferable without space and activity restrictions; however, previously reported systems are still heavy and bulky and induce unnatural movement. Therefore, a slim and light plantar pressure sensor was newly developed to detect the effect of sex difference on plantar pressure during standing and walking.Methods: One-hundred healthy adult volunteers (50 women and 50 men) were recruited. Ten plantar pressure sensors were implanted in a 1-mm thick insole, with a total weight of 29 g. Plantar pressure was recorded with 200 Hz during 3 seconds of standing and while walking 10 steps. The maximum loads during standing and walking were analyzed in each sensor, and the results were compared between different areas of the foot in the antero-posterior direction and the medio-lateral direction and between different time points. The movement of the center of pressure (COP) during walking was also evaluated. Results were compared between sexes by converting body mass index (BMI) to 22.Results: The movement of COP was constant for both sexes. In all cases, the maximum load was observed on the medial of the foot. Women had a significantly higher peak pressure on the hallux, toes, forefoot, and medial of the foot compared to men while standing and walking (P < .05).Conclusions: A newly introduced in-shoe plantar pressure sensor demonstrated a typical loading transition pattern of the foot. Furthermore, higher plantar pressure in the forefoot was detected in healthy women as compared to men during standing and walking activities.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Background: Sex-related differences of plantar pressure distribution during activities should be thoroughly inspected as it can help establish treatment and prevention strategies for foot and ankle problems. In-shoe measurement systems are preferable without space and activity restrictions; however, previously reported systems are still heavy and bulky and induce unnatural movement. Therefore, a slim and light plantar pressure sensor was newly developed to detect the effect of sex difference on plantar pressure during standing and walking.Methods: One-hundred healthy adult volunteers (50 women and 50 men) were recruited. Ten plantar pressure sensors were implanted in a 1-mm thick insole, with a total weight of 29 g. Plantar pressure was recorded with 200 Hz during 3 seconds of standing and while walking 10 steps. The maximum loads during standing and walking were analyzed in each sensor, and the results were compared between different areas of the foot in the antero-posterior direction and the medio-lateral direction and between different time points. The movement of the center of pressure (COP) during walking was also evaluated. Results were compared between sexes by converting body mass index (BMI) to 22.Results: The movement of COP was constant for both sexes. In all cases, the maximum load was observed on the medial of the foot. Women had a significantly higher peak pressure on the hallux, toes, forefoot, and medial of the foot compared to men while standing and walking (P < .05).Conclusions: A newly introduced in-shoe plantar pressure sensor demonstrated a typical loading transition pattern of the foot. Furthermore, higher plantar pressure in the forefoot was detected in healthy women as compared to men during standing and walking activities.

Key concepts: Forefoot, Plantar pressure, Foot (prosody), Foot pressure, Medicine, First metatarsal, Anatomy, Orthodontics

Related papers

Back to paper searchBrowse research topicsOriginal source
Plantar pressure sensors indicate women to have a significantly higher peak pressure on the hallux, toes, forefoot, and medial of the foot compared to men — Research Paper | ScholarLens