1990Catheterization and Cardiovascular DiagnosisRequires access

Reduction in radiation exposure during coronary angiography

Margot L. Carpenter, Peggy R. Singer, Avanindra Jain, Gregory Dehmer

Open publisher page 6 citations

Abstract

Abstract In addition to lead shielding, increased distance between the operator and x‐ray source will lower radiation exposure. To utilize this principle, we interposed a 24 in. piece of pressure tubing between the catheter used for coronary angiography and the manifold apparatus. Radiation exposure to the hand of the operator during coronary angiography was compared with and without the extension tubing. When corrected for the differences in exposure time, operator exposure was 5.38 mrem/min without the extension and 4.84 mrem/min with the extension. Although this is a small difference in exposure/min, a substantial reduction in exposure could accumulate over a 1 yr period. Insertion of this extension tube into the catheter system is a simple and safe way to further reduce operator exposure during coronary angiography.

About this research paper

What this paper is about

Abstract In addition to lead shielding, increased distance between the operator and x‐ray source will lower radiation exposure. To utilize this principle, we interposed a 24 in. piece of pressure tubing between the catheter used for coronary angiography and the manifold apparatus. Radiation exposure to the hand of the operator during coronary angiography was compared with and without the extension tubing. When corrected for the differences in exposure time, operator exposure was 5.38 mrem/min without the extension and 4.84 mrem/min with the extension. Although this is a small difference in exposure/min, a substantial reduction in exposure could accumulate over a 1 yr period. Insertion of this extension tube into the catheter system is a simple and safe way to further reduce operator exposure during coronary angiography.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract In addition to lead shielding, increased distance between the operator and x‐ray source will lower radiation exposure. To utilize this principle, we interposed a 24 in. piece of pressure tubing between the catheter used for coronary angiography and the manifold apparatus. Radiation exposure to the hand of the operator during coronary angiography was compared with and without the extension tubing. When corrected for the differences in exposure time, operator exposure was 5.38 mrem/min without the extension and 4.84 mrem/min with the extension. Although this is a small difference in exposure/min, a substantial reduction in exposure could accumulate over a 1 yr period. Insertion of this extension tube into the catheter system is a simple and safe way to further reduce operator exposure during coronary angiography.

Key concepts: Medicine, Coronary angiography, Radiation exposure, Angiography, Radiology, Cardiology, Internal medicine, Nuclear medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Reduction in radiation exposure during coronary angiography — Research Paper | ScholarLens