2012Unpublished venueRequires access

Energy resolution contributions in reach-through avalanche photodiodes

L. M. P. Fernandes, Andrea L. Gouvea, J.M.F. dos Santos, F. Kottmann

Open publisher page 0 citations

Abstract

Avalanche photodiodes (APDs) will be used in the muonic helium Lamb shift experiment for detection of 8 keV X-rays. Reach-through APDs (RT-APDs) from Hamamatsu Photonics have been investigated for X-ray detection as an alternative to conventional APDs. In order to understand the behavior of the energy resolution obtained in a RT-APD for 8 keV X-rays, the APD response to visible light pulses from a LED has also been investigated. The gain non-uniformity is determined from the comparison of the energy resolution obtained for X-rays and light pulses. In addition, the measurement of the electronic noise contribution allows the determination of the excess noise factor. Results at different temperatures are shown.

About this research paper

What this paper is about

Avalanche photodiodes (APDs) will be used in the muonic helium Lamb shift experiment for detection of 8 keV X-rays. Reach-through APDs (RT-APDs) from Hamamatsu Photonics have been investigated for X-ray detection as an alternative to conventional APDs. In order to understand the behavior of the energy resolution obtained in a RT-APD for 8 keV X-rays, the APD response to visible light pulses from a LED has also been investigated. The gain non-uniformity is determined from the comparison of the energy resolution obtained for X-rays and light pulses. In addition, the measurement of the electronic noise contribution allows the determination of the excess noise factor. Results at different temperatures are shown.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Avalanche photodiodes (APDs) will be used in the muonic helium Lamb shift experiment for detection of 8 keV X-rays. Reach-through APDs (RT-APDs) from Hamamatsu Photonics have been investigated for X-ray detection as an alternative to conventional APDs. In order to understand the behavior of the energy resolution obtained in a RT-APD for 8 keV X-rays, the APD response to visible light pulses from a LED has also been investigated. The gain non-uniformity is determined from the comparison of the energy resolution obtained for X-rays and light pulses. In addition, the measurement of the electronic noise contribution allows the determination of the excess noise factor. Results at different temperatures are shown.

Key concepts: APDS, Avalanche photodiode, Physics, Optics, Photonics, Noise (video), Photodiode, Optoelectronics

Related papers

Back to paper searchBrowse research topicsOriginal source
Energy resolution contributions in reach-through avalanche photodiodes — Research Paper | ScholarLens