2020American Society of Civil Engineers eBooksRequires access

Commercial Building with Monoslope Roof and Overhang

Author information unavailable

Open publisher page 0 citations

Abstract

This chapter presents the determination of design pressures for a typical retail store in a strip mall. The building does not meet the requirements of ASCE 7-16 for a simple diaphragm building, because the roof is not flat, gable, or hip; therefore, the simplified procedure described in this standard cannot be used. If the roof is not gable, flat, or hip, the low-rise building provisions of ASCE 7-16 should not be used, and the directional procedure for Main Wind Force Resisting Systems (MWFRS) is used instead. Because the building has a monoslope roof, the roof surface for wind directed parallel to the slope may be windward or leeward. The zones for roof overhangs are different from the zones for a monoslope roof. Tables are included that provide data for commercial buildings with monoslope roofs and overhangs, as well as design pressures for MWFRS for wind parallel- and normal-to-roof slopes, and normal- and parallel-to-ridge lines.

About this research paper

What this paper is about

This chapter presents the determination of design pressures for a typical retail store in a strip mall. The building does not meet the requirements of ASCE 7-16 for a simple diaphragm building, because the roof is not flat, gable, or hip; therefore, the simplified procedure described in this standard cannot be used. If the roof is not gable, flat, or hip, the low-rise building provisions of ASCE 7-16 should not be used, and the directional procedure for Main Wind Force Resisting Systems (MWFRS) is used instead. Because the building has a monoslope roof, the roof surface for wind directed parallel to the slope may be windward or leeward. The zones for roof overhangs are different from the zones for a monoslope roof. Tables are included that provide data for commercial buildings with monoslope roofs and overhangs, as well as design pressures for MWFRS for wind parallel- and normal-to-roof slopes, and normal- and parallel-to-ridge lines.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This chapter presents the determination of design pressures for a typical retail store in a strip mall. The building does not meet the requirements of ASCE 7-16 for a simple diaphragm building, because the roof is not flat, gable, or hip; therefore, the simplified procedure described in this standard cannot be used. If the roof is not gable, flat, or hip, the low-rise building provisions of ASCE 7-16 should not be used, and the directional procedure for Main Wind Force Resisting Systems (MWFRS) is used instead. Because the building has a monoslope roof, the roof surface for wind directed parallel to the slope may be windward or leeward. The zones for roof overhangs are different from the zones for a monoslope roof. Tables are included that provide data for commercial buildings with monoslope roofs and overhangs, as well as design pressures for MWFRS for wind parallel- and normal-to-roof slopes, and normal- and parallel-to-ridge lines.

Key concepts: Roof, Gable, Flat roof, Ridge, Structural engineering, Low-rise, Engineering, Geology