2003•1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019)Requires access

X-ray detection characteristics of thallium bromide nuclear radiation detectors

Keitaro Hitomi, O. Muroi, M. Matsumoto, R. Hirabuki, T. Shoji, Y. Hiratate

Open publisher page 0 citations

Abstract

Semiconductor X-ray detectors have been fabricated from high purity TlBr crystals grown by the traveling molten zone method. X-ray detection characteristics of the TlBr detectors in the individual quantum pulse mode as well as in the current mode have been studied. An energy resolution of 2.5 keV FWHM has been recorded for 22 keV X-rays with a TlBr detector operated in the individual quantum pulse mode at room temperature. The TlBr detectors in the current mode have been tested as flux detectors for an X-ray CT scanner system of a first generation type. The performance of the system has been tested using a wooden phantom. The X-ray CT system has shown good imaging capabilities.

About this research paper

What this paper is about

Semiconductor X-ray detectors have been fabricated from high purity TlBr crystals grown by the traveling molten zone method. X-ray detection characteristics of the TlBr detectors in the individual quantum pulse mode as well as in the current mode have been studied. An energy resolution of 2.5 keV FWHM has been recorded for 22 keV X-rays with a TlBr detector operated in the individual quantum pulse mode at room temperature. The TlBr detectors in the current mode have been tested as flux detectors for an X-ray CT scanner system of a first generation type. The performance of the system has been tested using a wooden phantom. The X-ray CT system has shown good imaging capabilities.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Semiconductor X-ray detectors have been fabricated from high purity TlBr crystals grown by the traveling molten zone method. X-ray detection characteristics of the TlBr detectors in the individual quantum pulse mode as well as in the current mode have been studied. An energy resolution of 2.5 keV FWHM has been recorded for 22 keV X-rays with a TlBr detector operated in the individual quantum pulse mode at room temperature. The TlBr detectors in the current mode have been tested as flux detectors for an X-ray CT scanner system of a first generation type. The performance of the system has been tested using a wooden phantom. The X-ray CT system has shown good imaging capabilities.

Key concepts: X-ray detector, Detector, Particle detector, Semiconductor detector, Full width at half maximum, Optics, Materials science, Scanner

Related papers

Back to paper searchBrowse research topicsOriginal source
X-ray detection characteristics of thallium bromide nuclear radiation detectors — Research Paper | ScholarLens