2002Unpublished venueRequires access

Dose uniformity of a compact beamline in routine operation with a storage ring "AURORA-2S"

S. Hirose, D. Amano, T. Miyatake, Xan Li, T. Hori

Open publisher page 1 citations

Abstract

In 1998, we developed a short beamline with high brightness for x-ray lithography. In 1999, the beamline which is installed in our Tanashi-plan has achieved a dose uniformity better than /spl plusmn/5 % with an exposure intensity over 60 mW/cm/sup 2/ using a synchrotron radiation (SR) beam from a storage ring "AURORA-2S (A2S)". In routine operation, the position of SR beam moves in a range of 0.15 mm in horizontal direction and 0.1 mm in vertical direction. The beam profile varies from round shape to oval shape with an operation parameter. In this paper, we describe the impact of both the beam profile and beam position stability on dose uniformity of the beamline.

About this research paper

What this paper is about

In 1998, we developed a short beamline with high brightness for x-ray lithography. In 1999, the beamline which is installed in our Tanashi-plan has achieved a dose uniformity better than /spl plusmn/5 % with an exposure intensity over 60 mW/cm/sup 2/ using a synchrotron radiation (SR) beam from a storage ring "AURORA-2S (A2S)". In routine operation, the position of SR beam moves in a range of 0.15 mm in horizontal direction and 0.1 mm in vertical direction. The beam profile varies from round shape to oval shape with an operation parameter. In this paper, we describe the impact of both the beam profile and beam position stability on dose uniformity of the beamline.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In 1998, we developed a short beamline with high brightness for x-ray lithography. In 1999, the beamline which is installed in our Tanashi-plan has achieved a dose uniformity better than /spl plusmn/5 % with an exposure intensity over 60 mW/cm/sup 2/ using a synchrotron radiation (SR) beam from a storage ring "AURORA-2S (A2S)". In routine operation, the position of SR beam moves in a range of 0.15 mm in horizontal direction and 0.1 mm in vertical direction. The beam profile varies from round shape to oval shape with an operation parameter. In this paper, we describe the impact of both the beam profile and beam position stability on dose uniformity of the beamline.

Key concepts: Beamline, Storage ring, Optics, Synchrotron radiation, Beam (structure), Synchrotron, Brightness, Physics

Related papers

Back to paper searchBrowse research topicsOriginal source
Dose uniformity of a compact beamline in routine operation with a storage ring "AURORA-2S" — Research Paper | ScholarLens