2000Obstetrics and GynecologyRequires access

First-Trimester Down Syndrome Screening Using Dried Blood Biochemistry and Nuchal Translucency

David Krantz, Terrence Hallahan, Francesco Orlandi, Philip D. Buchanan, John W. Larsen, James N. Macri

Open publisher page 16 citations

Abstract

In Brief Objective To assess the effectiveness of free β-hCG, pregnancy-associated plasma protein A, and nuchal translucency in a prospective first-trimester prenatal screening study for Down syndrome and trisomy 18. Methods Risks were calculated for Down syndrome and trisomy 18 based on maternal age and biochemistry only (n = 10,251), nuchal translucency only (n = 5809), and the combination of nuchal translucency and biochemistry (n = 5809). Results The study population included 50 Down syndrome and 20 trisomy 18 cases. Nuchal translucency measurement was done on 33 Down syndrome and 13 trisomy 18 cases. Down syndrome screening using combined biochemistry and ultrasound resulted in a false-positive rate of 4.5% (95% confidence interval [CI] 3.9%, 5.2%) and detection rate of 87.5% (95% CI 47%, 100%) in patients under age 35 years. In older patients, the false-positive rate was 14.3% (95% CI 12.7%, 15.8%) and detection rate was 92% (95% CI 74%, 99%). For trisomy 18 screening, the false-positive rate was 0.4% (95% CI 0.24%, 0.69%) and detection rate was 100% (95% CI 40%, 100%) in younger patients, whereas in older patients the false-positive rate was 1.4% (95% CI 0.9%, 2.0%) and detection rate was 100% (95% CI 66%, 100%). Using modeling, at a fixed 5% false-positive rate, the Down syndrome detection rate was 91%. Conversely, at a fixed 70% Down syndrome detection rate, the false-positive rate was 1.4%. Conclusion First-trimester screening for Down syndrome and trisomy 18 is effective and offers substantial benefits to clinicians and patients. First-trimester screening for Down syndrome and trisomy 18 is effective and results in identification of a high yield of affected cases for each diagnostic procedure done.

About this research paper

What this paper is about

In Brief Objective To assess the effectiveness of free β-hCG, pregnancy-associated plasma protein A, and nuchal translucency in a prospective first-trimester prenatal screening study for Down syndrome and trisomy 18. Methods Risks were calculated for Down syndrome and trisomy 18 based on maternal age and biochemistry only (n = 10,251), nuchal translucency only (n = 5809), and the combination of nuchal translucency and biochemistry (n = 5809). Results The study population included 50 Down syndrome and 20 trisomy 18 cases. Nuchal translucency measurement was done on 33 Down syndrome and 13 trisomy 18 cases. Down syndrome screening using combined biochemistry and ultrasound resulted in a false-positive rate of 4.5% (95% confidence interval [CI] 3.9%, 5.2%) and detection rate of 87.5% (95% CI 47%, 100%) in patients under age 35 years. In older patients, the false-positive rate was 14.3% (95% CI 12.7%, 15.8%) and detection rate was 92% (95% CI 74%, 99%). For trisomy 18 screening, the false-positive rate was 0.4% (95% CI 0.24%, 0.69%) and detection rate was 100% (95% CI 40%, 100%) in younger patients, whereas in older patients the false-positive rate was 1.4% (95% CI 0.9%, 2.0%) and detection rate was 100% (95% CI 66%, 100%). Using modeling, at a fixed 5% false-positive rate, the Down syndrome detection rate was 91%. Conversely, at a fixed 70% Down syndrome detection rate, the false-positive rate was 1.4%. Conclusion First-trimester screening for Down syndrome and trisomy 18 is effective and offers substantial benefits to clinicians and patients. First-trimester screening for Down syndrome and trisomy 18 is effective and results in identification of a high yield of affected cases for each diagnostic procedure done.

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In Brief Objective To assess the effectiveness of free β-hCG, pregnancy-associated plasma protein A, and nuchal translucency in a prospective first-trimester prenatal screening study for Down syndrome and trisomy 18. Methods Risks were calculated for Down syndrome and trisomy 18 based on maternal age and biochemistry only (n = 10,251), nuchal translucency only (n = 5809), and the combination of nuchal translucency and biochemistry (n = 5809). Results The study population included 50 Down syndrome and 20 trisomy 18 cases. Nuchal translucency measurement was done on 33 Down syndrome and 13 trisomy 18 cases. Down syndrome screening using combined biochemistry and ultrasound resulted in a false-positive rate of 4.5% (95% confidence interval [CI] 3.9%, 5.2%) and detection rate of 87.5% (95% CI 47%, 100%) in patients under age 35 years. In older patients, the false-positive rate was 14.3% (95% CI 12.7%, 15.8%) and detection rate was 92% (95% CI 74%, 99%). For trisomy 18 screening, the false-positive rate was 0.4% (95% CI 0.24%, 0.69%) and detection rate was 100% (95% CI 40%, 100%) in younger patients, whereas in older patients the false-positive rate was 1.4% (95% CI 0.9%, 2.0%) and detection rate was 100% (95% CI 66%, 100%). Using modeling, at a fixed 5% false-positive rate, the Down syndrome detection rate was 91%. Conversely, at a fixed 70% Down syndrome detection rate, the false-positive rate was 1.4%. Conclusion First-trimester screening for Down syndrome and trisomy 18 is effective and offers substantial benefits to clinicians and patients. First-trimester screening for Down syndrome and trisomy 18 is effective and results in identification of a high yield of affected cases for each diagnostic procedure done.

Key concepts: Trisomy, Medicine, Down syndrome, Obstetrics, Nuchal Translucency Measurement, False positive rate, Aneuploidy, Confidence interval

Related papers

Back to paper searchBrowse research topicsOriginal source
First-Trimester Down Syndrome Screening Using Dried Blood Biochemistry and Nuchal Translucency — Research Paper | ScholarLens