Effect of genotypes on the quantification of hepatitis C virus (HCV) RNA in clinical samples using the amplicor HCV monitor test and the quantiplex HCV RNA 2.0 assay (bDNA)

C.Y.W. Tong, R.C. Hollingsworth, H. Williams, W.L. Irving, I.T. Gilmore

Open publisher page 0 citations

Abstract

The Amplicor HCV Monitor test and the Quantiplex HCV RNA 2.0 (bDNA) assay are two commercially available assays for the quantification of hepatitis C virus (HCV) RNA in clinical samples. A direct comparison of the two assays was carried out using sera frozen previously from patients known to be chronically infected with HCV. Overall, 61 samples from 51 patients were tested simultaneously by the two methods: 67% (28/42) of the patients were infected by HCV genotype/serotype 1, 10 % (4/42) with type 2, and 24% (10/42) with type 3. When the absolute value from each assay was examined, the Quantiplex assay gave a consistently higher reading and the mean logarithmic difference between the two assays was 1.4 (1.0 in type 1, 2.0 in type 2, and 2.2 in type 3). When analyzed according to genotype, strong correlation was observed between the two assays for type 1 (r = 0.83, 95% CI 0.63–0.93, P < 0.01), but not for nontype 1 samples. Despite the difference in absolute level reported by the two assays, there was a consistent trend of change in HCV RNA concentration by both assays in patients whose consecutive samples were analyzed and the differences between the two assays in consecutive samples were within 0.4 log of each other. The results suggested that with samples containing genotype 1, the Amplicor assay was more sensitive than the Quantiplex assay by about one log. However, the sensitivities of the two assays with nontype 1 samples were much closer probably due to the failure of the Amplicor assay to quantify nontype 1 genotypes effectively. J. Med. Virol. 55:191–196, 1998. © 1998 Wiley-Liss, Inc.

About this research paper

What this paper is about

The Amplicor HCV Monitor test and the Quantiplex HCV RNA 2.0 (bDNA) assay are two commercially available assays for the quantification of hepatitis C virus (HCV) RNA in clinical samples. A direct comparison of the two assays was carried out using sera frozen previously from patients known to be chronically infected with HCV. Overall, 61 samples from 51 patients were tested simultaneously by the two methods: 67% (28/42) of the patients were infected by HCV genotype/serotype 1, 10 % (4/42) with type 2, and 24% (10/42) with type 3. When the absolute value from each assay was examined, the Quantiplex assay gave a consistently higher reading and the mean logarithmic difference between the two assays was 1.4 (1.0 in type 1, 2.0 in type 2, and 2.2 in type 3). When analyzed according to genotype, strong correlation was observed between the two assays for type 1 (r = 0.83, 95% CI 0.63–0.93, P < 0.01), but not for nontype 1 samples. Despite the difference in absolute level reported by the two assays, there was a consistent trend of change in HCV RNA concentration by both assays in patients whose consecutive samples were analyzed and the differences between the two assays in consecutive samples were within 0.4 log of each other. The results suggested that with samples containing genotype 1, the Amplicor assay was more sensitive than the Quantiplex assay by about one log. However, the sensitivities of the two assays with nontype 1 samples were much closer probably due to the failure of the Amplicor assay to quantify nontype 1 genotypes effectively. J. Med. Virol. 55:191–196, 1998. © 1998 Wiley-Liss, Inc.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The Amplicor HCV Monitor test and the Quantiplex HCV RNA 2.0 (bDNA) assay are two commercially available assays for the quantification of hepatitis C virus (HCV) RNA in clinical samples. A direct comparison of the two assays was carried out using sera frozen previously from patients known to be chronically infected with HCV. Overall, 61 samples from 51 patients were tested simultaneously by the two methods: 67% (28/42) of the patients were infected by HCV genotype/serotype 1, 10 % (4/42) with type 2, and 24% (10/42) with type 3. When the absolute value from each assay was examined, the Quantiplex assay gave a consistently higher reading and the mean logarithmic difference between the two assays was 1.4 (1.0 in type 1, 2.0 in type 2, and 2.2 in type 3). When analyzed according to genotype, strong correlation was observed between the two assays for type 1 (r = 0.83, 95% CI 0.63–0.93, P < 0.01), but not for nontype 1 samples. Despite the difference in absolute level reported by the two assays, there was a consistent trend of change in HCV RNA concentration by both assays in patients whose consecutive samples were analyzed and the differences between the two assays in consecutive samples were within 0.4 log of each other. The results suggested that with samples containing genotype 1, the Amplicor assay was more sensitive than the Quantiplex assay by about one log. However, the sensitivities of the two assays with nontype 1 samples were much closer probably due to the failure of the Amplicor assay to quantify nontype 1 genotypes effectively. J. Med. Virol. 55:191–196, 1998. © 1998 Wiley-Liss, Inc.

Key concepts: BDNA test, Virology, Hepatitis C virus, Genotype, Hepacivirus, Biology, Flaviviridae, Virus

Related papers

Back to paper searchBrowse research topicsOriginal source
Effect of genotypes on the quantification of hepatitis C virus (HCV) RNA in clinical samples using the amplicor HCV monitor test and the quantiplex HCV RNA 2.0 assay (bDNA) — Research Paper | ScholarLens