1973Journal of Research of the National Bureau of Standards Section A Physics and ChemistryOpen access

The International Practical Temperature Scale of 1968 in region 13.81 K to 90.188 K as maintained at the National Bureau of Standards

George T. Furukawa, John L. Riddle, William R. Bigge

Open full text 15 citations

Abstract

The reproducibility of the International Practical Temperature Scale of 1968 (IPTS-68) in the region of 13.81 K to 90.188 K using standard platinum resistance thermometers is discussed. The effect of errors above 0 °C on the calibration between 13 and 90 K is analyzed. Calibrations resulting from least squares and "fixed point" treatment of the data are compared. The results show that in general the NBS-IPTS-68 temperature scale maintained at the National Bureau of Standards (NBS) by reference standard platinum resistance thermometers is transferred to thermometers calibrated at the NBS within a few tenths of a mK between about 20 and 90.188 K and within about ±1 mK between 13.81 and 20 K. Agreements within a few mK are shown between the observed values of temperatures, employing platinum resistance thermometers calibrated in terms of the NBS-IPTS-68 scale, and the values of temperatures of the fixed points in the region 13.81 to 90.188 K given in the text of the IPTS-68.

About this research paper

What this paper is about

The reproducibility of the International Practical Temperature Scale of 1968 (IPTS-68) in the region of 13.81 K to 90.188 K using standard platinum resistance thermometers is discussed. The effect of errors above 0 °C on the calibration between 13 and 90 K is analyzed. Calibrations resulting from least squares and "fixed point" treatment of the data are compared. The results show that in general the NBS-IPTS-68 temperature scale maintained at the National Bureau of Standards (NBS) by reference standard platinum resistance thermometers is transferred to thermometers calibrated at the NBS within a few tenths of a mK between about 20 and 90.188 K and within about ±1 mK between 13.81 and 20 K. Agreements within a few mK are shown between the observed values of temperatures, employing platinum resistance thermometers calibrated in terms of the NBS-IPTS-68 scale, and the values of temperatures of the fixed points in the region 13.81 to 90.188 K given in the text of the IPTS-68.

Why it matters

OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The reproducibility of the International Practical Temperature Scale of 1968 (IPTS-68) in the region of 13.81 K to 90.188 K using standard platinum resistance thermometers is discussed. The effect of errors above 0 °C on the calibration between 13 and 90 K is analyzed. Calibrations resulting from least squares and "fixed point" treatment of the data are compared. The results show that in general the NBS-IPTS-68 temperature scale maintained at the National Bureau of Standards (NBS) by reference standard platinum resistance thermometers is transferred to thermometers calibrated at the NBS within a few tenths of a mK between about 20 and 90.188 K and within about ±1 mK between 13.81 and 20 K. Agreements within a few mK are shown between the observed values of temperatures, employing platinum resistance thermometers calibrated in terms of the NBS-IPTS-68 scale, and the values of temperatures of the fixed points in the region 13.81 to 90.188 K given in the text of the IPTS-68.

Key concepts: International Temperature Scale of 1990, Scale of temperature, Resistance thermometer, Calibration, Platinum, Scale (ratio), Reproducibility, National standard

Related papers

Back to paper searchBrowse research topicsOriginal source
The International Practical Temperature Scale of 1968 in region 13.81 K to 90.188 K as maintained at the National Bureau of Standards — Research Paper | ScholarLens