The International Practical Temperature Scale of 1968 in region 13.81 K to 90.188 K as maintained at the National Bureau of Standards
George T. Furukawa, John L. Riddle, William R. Bigge
Abstract
George T. Furukawa, John L. Riddle, William R. Bigge
Abstract
The reproducibility of the International Practical Temperature Scale of 1968 (IPTS-68) in the region of 13.81 K to 90.188 K using standard platinum resistance thermometers is discussed. The effect of errors above 0 °C on the calibration between 13 and 90 K is analyzed. Calibrations resulting from least squares and "fixed point" treatment of the data are compared. The results show that in general the NBS-IPTS-68 temperature scale maintained at the National Bureau of Standards (NBS) by reference standard platinum resistance thermometers is transferred to thermometers calibrated at the NBS within a few tenths of a mK between about 20 and 90.188 K and within about ±1 mK between 13.81 and 20 K. Agreements within a few mK are shown between the observed values of temperatures, employing platinum resistance thermometers calibrated in terms of the NBS-IPTS-68 scale, and the values of temperatures of the fixed points in the region 13.81 to 90.188 K given in the text of the IPTS-68.
OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The reproducibility of the International Practical Temperature Scale of 1968 (IPTS-68) in the region of 13.81 K to 90.188 K using standard platinum resistance thermometers is discussed. The effect of errors above 0 °C on the calibration between 13 and 90 K is analyzed. Calibrations resulting from least squares and "fixed point" treatment of the data are compared. The results show that in general the NBS-IPTS-68 temperature scale maintained at the National Bureau of Standards (NBS) by reference standard platinum resistance thermometers is transferred to thermometers calibrated at the NBS within a few tenths of a mK between about 20 and 90.188 K and within about ±1 mK between 13.81 and 20 K. Agreements within a few mK are shown between the observed values of temperatures, employing platinum resistance thermometers calibrated in terms of the NBS-IPTS-68 scale, and the values of temperatures of the fixed points in the region 13.81 to 90.188 K given in the text of the IPTS-68.
Key concepts: International Temperature Scale of 1990, Scale of temperature, Resistance thermometer, Calibration, Platinum, Scale (ratio), Reproducibility, National standard