1942Electrical EngineeringRequires access

Design and operation of high-voltage axial air-blast circuit breakers

Armin K. Leuthold

Open publisher page 0 citations

Abstract

The air-blast high-voltage circuit breaker has been developed and applied on high-voltage systems of 150 and 240 kv. Both single-phase and three-phase automatic high-speed reclosing can be carried out with this new type of circuit breaker. The principles of design and operation are explained and the construction of two high-voltage air-blast circuit breakers rated at 150 kv and 220 kv, installed in Canadian power-distribution plants, is described and supplemented by a discussion of performance tests and oscillograms. The construction of an air-blast circuit breaker with axial blast, designed for extremely high voltage and high interrupting capacity, is explained, and results of various tests discussed.

About this research paper

What this paper is about

The air-blast high-voltage circuit breaker has been developed and applied on high-voltage systems of 150 and 240 kv. Both single-phase and three-phase automatic high-speed reclosing can be carried out with this new type of circuit breaker. The principles of design and operation are explained and the construction of two high-voltage air-blast circuit breakers rated at 150 kv and 220 kv, installed in Canadian power-distribution plants, is described and supplemented by a discussion of performance tests and oscillograms. The construction of an air-blast circuit breaker with axial blast, designed for extremely high voltage and high interrupting capacity, is explained, and results of various tests discussed.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The air-blast high-voltage circuit breaker has been developed and applied on high-voltage systems of 150 and 240 kv. Both single-phase and three-phase automatic high-speed reclosing can be carried out with this new type of circuit breaker. The principles of design and operation are explained and the construction of two high-voltage air-blast circuit breakers rated at 150 kv and 220 kv, installed in Canadian power-distribution plants, is described and supplemented by a discussion of performance tests and oscillograms. The construction of an air-blast circuit breaker with axial blast, designed for extremely high voltage and high interrupting capacity, is explained, and results of various tests discussed.

Key concepts: Circuit breaker, Sulfur hexafluoride circuit breaker, High voltage, Electrical engineering, Voltage, Engineering, Air blast, Transient recovery voltage

Related papers

Back to paper searchBrowse research topicsOriginal source
Design and operation of high-voltage axial air-blast circuit breakers — Research Paper | ScholarLens