2005Clinical & Laboratory HaematologyRequires access

Thrombelastography/thromboelastometry

R. Luddington

Open publisher page 657 citations

Abstract

The term thrombelastograph (TEG) was used to describe the trace produced from the measurement of the viscoelastic changes associated with fibrin polymerization. Recently the term rotational thromboelastometry has been applied to the output of the ROTEM instrument. Since its first description in 1948, the TEG/ROTEM has been successfully used in the near patient assessment of haemostasis. The greatest use has been the application of TEG-guided transfusion of blood components in hepatic and more widely in cardiac surgery. Recent years have seen a renewed interest in the technology with applications for both pharmaceutical monitoring and patient screening being described. The present review gives a broad overview of the developments and applications related to thrombelastography/thromboelastometry.

About this research paper

What this paper is about

The term thrombelastograph (TEG) was used to describe the trace produced from the measurement of the viscoelastic changes associated with fibrin polymerization. Recently the term rotational thromboelastometry has been applied to the output of the ROTEM instrument. Since its first description in 1948, the TEG/ROTEM has been successfully used in the near patient assessment of haemostasis. The greatest use has been the application of TEG-guided transfusion of blood components in hepatic and more widely in cardiac surgery. Recent years have seen a renewed interest in the technology with applications for both pharmaceutical monitoring and patient screening being described. The present review gives a broad overview of the developments and applications related to thrombelastography/thromboelastometry.

Why it matters

OpenAlex reports 657 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The term thrombelastograph (TEG) was used to describe the trace produced from the measurement of the viscoelastic changes associated with fibrin polymerization. Recently the term rotational thromboelastometry has been applied to the output of the ROTEM instrument. Since its first description in 1948, the TEG/ROTEM has been successfully used in the near patient assessment of haemostasis. The greatest use has been the application of TEG-guided transfusion of blood components in hepatic and more widely in cardiac surgery. Recent years have seen a renewed interest in the technology with applications for both pharmaceutical monitoring and patient screening being described. The present review gives a broad overview of the developments and applications related to thrombelastography/thromboelastometry.

Key concepts: Thromboelastometry, Thrombelastography, Medicine, Fibrin, Surgery, Whole blood, Platelet, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Thrombelastography/thromboelastometry — Research Paper | ScholarLens