1969The Journal of the Acoustical Society of AmericaRequires access

Hydrophone Calibrator

W. James Trott

Open publisher page 1 citations

Abstract

The USA Standard procedure for calibrating a hydrophone at low frequencies is the two-projector null method in which the two projectors are electrodynamic. A. N. Golenkov, USSR, developed a calibrator on the same principle using two piezoelectric projectors. A new calibrator, using piezoceramic cylinders for projector and receiver, has been developed that eliminates the null balance requirement and thus simplifies the calibration procedure. The reference is again a step change in water head achieved by a two-way valve that connects one manometer and then a second. An absolute calibration of a hydrophone can be made up to 4 kHz and for hydrostatic pressures from 0 to 2000 psi.

About this research paper

What this paper is about

The USA Standard procedure for calibrating a hydrophone at low frequencies is the two-projector null method in which the two projectors are electrodynamic. A. N. Golenkov, USSR, developed a calibrator on the same principle using two piezoelectric projectors. A new calibrator, using piezoceramic cylinders for projector and receiver, has been developed that eliminates the null balance requirement and thus simplifies the calibration procedure. The reference is again a step change in water head achieved by a two-way valve that connects one manometer and then a second. An absolute calibration of a hydrophone can be made up to 4 kHz and for hydrostatic pressures from 0 to 2000 psi.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The USA Standard procedure for calibrating a hydrophone at low frequencies is the two-projector null method in which the two projectors are electrodynamic. A. N. Golenkov, USSR, developed a calibrator on the same principle using two piezoelectric projectors. A new calibrator, using piezoceramic cylinders for projector and receiver, has been developed that eliminates the null balance requirement and thus simplifies the calibration procedure. The reference is again a step change in water head achieved by a two-way valve that connects one manometer and then a second. An absolute calibration of a hydrophone can be made up to 4 kHz and for hydrostatic pressures from 0 to 2000 psi.

Key concepts: Hydrophone, Projector, Calibration, Acoustics, Null (SQL), Hydrostatic equilibrium, Underwater, Piezoelectricity