Diagnostic Performance of Optical Coherence Tomography and Nonspecialist Gonioscopy to Detect Angle Closure

Norma Allemann, Bruno L. B. Esporcatte, Roberto M. Vessani, Luiz AS Melo, Norton Sakassegawa Yanagimori, Guilherme Havir Bufarah, Ivan Maynart Tavares

Open full text 6 citations

Abstract

Aim: To compare the usefulness of gonioscopy performed by general ophthalmologists (GO) and anterior segment optical coherence tomography (AS-OCT) in detecting angle closure in patients with a shallow anterior chamber. Methods: Forty-four patients with a shallow anterior chamber (defined by a ratio of peripheral anterior chamber depth to peripheral corneal thickness lower than 1/2) were included in this cross-sectional study. Gonioscopy was performed in all subjects by two glaucoma experts (GE1 and GE2) and one GO. Anterior segment imaging was performed using Visante® OCT (Carl Zeiss Meditec Inc.). Agreement between examiners was assessed with first-order agreement coefficients (AC1). Diagnostic accuracies of GO gonioscopy and AS-OCT were evaluated using sensitivity, specificity, and area under the receiver operating characteristic (AROC) curves. Results: For static gonioscopy, the agreement between GE1 and GE2 was substantial (AC1 = 0.65), and that between GE1 and GO was moderate (AC1 = 0.50). For indentation gonioscopy, the agreement between GE1 and GE2 was slightly lower (AC1 = 0.55); however, the agreement between GE1 and GO showed a larger reduction (AC1 = 0.12). GO's gonioscopy presented a low specificity (25%) and the AROC to angle closure detection was lower than AS-OCT (0.56-0.73). Combined information of GO gonioscopy and AS-OCT improved specificity (85.7%) and AROC (0.77) of angle closure evaluation. Conclusion: Agreement between GO and glaucoma experts was moderate for static gonioscopy and slight for indentation gonioscopy. AS-OCT performed better than GO gonioscopy in detecting angle closure in patients with a shallow anterior chamber. The addition of AS-OCT to clinical information in patients with GO positive gonioscopy improved the specificity and AROC of gonioscopy test. How to cite this article: Diagnostic Performance of Optical Coherence Tomography and Nonspecialist Gonioscopy to Detect Angle Closure. J Curr Glaucoma Pract 2022;16(1):53-58.

Open-access reader

About this research paper

What this paper is about

Aim: To compare the usefulness of gonioscopy performed by general ophthalmologists (GO) and anterior segment optical coherence tomography (AS-OCT) in detecting angle closure in patients with a shallow anterior chamber. Methods: Forty-four patients with a shallow anterior chamber (defined by a ratio of peripheral anterior chamber depth to peripheral corneal thickness lower than 1/2) were included in this cross-sectional study. Gonioscopy was performed in all subjects by two glaucoma experts (GE1 and GE2) and one GO. Anterior segment imaging was performed using Visante® OCT (Carl Zeiss Meditec Inc.). Agreement between examiners was assessed with first-order agreement coefficients (AC1). Diagnostic accuracies of GO gonioscopy and AS-OCT were evaluated using sensitivity, specificity, and area under the receiver operating characteristic (AROC) curves. Results: For static gonioscopy, the agreement between GE1 and GE2 was substantial (AC1 = 0.65), and that between GE1 and GO was moderate (AC1 = 0.50). For indentation gonioscopy, the agreement between GE1 and GE2 was slightly lower (AC1 = 0.55); however, the agreement between GE1 and GO showed a larger reduction (AC1 = 0.12). GO's gonioscopy presented a low specificity (25%) and the AROC to angle closure detection was lower than AS-OCT (0.56-0.73). Combined information of GO gonioscopy and AS-OCT improved specificity (85.7%) and AROC (0.77) of angle closure evaluation. Conclusion: Agreement between GO and glaucoma experts was moderate for static gonioscopy and slight for indentation gonioscopy. AS-OCT performed better than GO gonioscopy in detecting angle closure in patients with a shallow anterior chamber. The addition of AS-OCT to clinical information in patients with GO positive gonioscopy improved the specificity and AROC of gonioscopy test. How to cite this article: Diagnostic Performance of Optical Coherence Tomography and Nonspecialist Gonioscopy to Detect Angle Closure. J Curr Glaucoma Pract 2022;16(1):53-58.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Aim: To compare the usefulness of gonioscopy performed by general ophthalmologists (GO) and anterior segment optical coherence tomography (AS-OCT) in detecting angle closure in patients with a shallow anterior chamber. Methods: Forty-four patients with a shallow anterior chamber (defined by a ratio of peripheral anterior chamber depth to peripheral corneal thickness lower than 1/2) were included in this cross-sectional study. Gonioscopy was performed in all subjects by two glaucoma experts (GE1 and GE2) and one GO. Anterior segment imaging was performed using Visante® OCT (Carl Zeiss Meditec Inc.). Agreement between examiners was assessed with first-order agreement coefficients (AC1). Diagnostic accuracies of GO gonioscopy and AS-OCT were evaluated using sensitivity, specificity, and area under the receiver operating characteristic (AROC) curves. Results: For static gonioscopy, the agreement between GE1 and GE2 was substantial (AC1 = 0.65), and that between GE1 and GO was moderate (AC1 = 0.50). For indentation gonioscopy, the agreement between GE1 and GE2 was slightly lower (AC1 = 0.55); however, the agreement between GE1 and GO showed a larger reduction (AC1 = 0.12). GO's gonioscopy presented a low specificity (25%) and the AROC to angle closure detection was lower than AS-OCT (0.56-0.73). Combined information of GO gonioscopy and AS-OCT improved specificity (85.7%) and AROC (0.77) of angle closure evaluation. Conclusion: Agreement between GO and glaucoma experts was moderate for static gonioscopy and slight for indentation gonioscopy. AS-OCT performed better than GO gonioscopy in detecting angle closure in patients with a shallow anterior chamber. The addition of AS-OCT to clinical information in patients with GO positive gonioscopy improved the specificity and AROC of gonioscopy test. How to cite this article: Diagnostic Performance of Optical Coherence Tomography and Nonspecialist Gonioscopy to Detect Angle Closure. J Curr Glaucoma Pract 2022;16(1):53-58.

Key concepts: Gonioscopy, Glaucoma, Ophthalmology, Medicine, Optical coherence tomography, Anterior chamber angle, Optometry, Optics